MECHANICAL DATA

UCFC300DQ-10/2

UCFC330DQ-12/2

UCFC360DQ-12/2

UCFC400DQ-14/2

UCFC450DQ-14/2

ALL DATA AS D MODEL EXCEPT:

Cooling Duty

DX Cooling Output

(1)

kW

303.2

340.7

365.8

414.5

451.9

Nom Input (Compressor only)

(1)

kW

105.2

112.4

126.7

137.8

158.0

EER - DX (Mechanical)

(2)

2.88

3.03

2.89

3.01

2.86

Free Cooling

(3)

kW

159.0

190.0

219.0

222.0

226.0

Dimensions

2180 x 2200 x

5570

2180 x 2200 x

6420

2180 x 2200 x

6400

2180 x 2200 x

7270

2180 x 2200 x 7270

H x W x L

mm

Weight

(4)

Machine

kg

3490

4110

4110

4540

4620

Operating

kg

3870

4550

4550

5050

5130

Condenser

Face Area (Total)

14.03

16.83

16.83

19.64

19.64

Nominal Airflow

m³/s

19.00

22.80

22.80

26.60

26.60

Fan & Motor

Quantity

10

12

12

14

14

Maximum Speed

rpm

750

750

750

750

750

Refrigeration

Charge (Total)

kg

47 + 47

57 + 53

55 + 55

66 + 60

64 + 64

OPTIONAL EXTRAS

(5)

kg

UCFC300DSQ-12/2 UCFC330DSQ-16/2 UCFC360DSQ-16/2 UCFC400DSQ-16/2 UCFC450DSQ-16/2

ALL DATA AS D MODEL EXCEPT:

Cooling Duty

DX Cooling Output

(1)

kW

301.8

341.0

366.0

403.6

438.2

Nom Input (Compressor only)

(1)

kW

105.9

112.3

126.6

144.4

165.5

EER - DX (Mechanical)

(2)

2.85

3.04

2.89

2.79

2.65

Free Cooling

(3)

kW

152.0

190.0

192.0

194.0

195.0

Dimensions

2180 x 2200 x

6420

2180 x 2200 x

8120

2180 x 2200 x

8120

2180 x 2200 x

8120

2180 x 2200 x

8120

H x W x L

mm

Weight

(4)

Machine

kg

3860

4840

4840

4910

4990

Operating

kg

4300

5400

5400

5470

5560

Condenser

Face Area (Total)

16.83

22.44

22.44

22.44

22.44

Nominal Airflow

m³/s

16.20

21.60

21.60

21.60

21.60

Fan & Motor

Quantity

12

16

16

16

16

Maximum Speed

rpm

570

570

570

570

570

Refrigeration

Charge (Total)

kg

54 + 54

74 + 68

71 + 71

74 + 68

72 + 72

OPTIONAL EXTRAS

(5)

kg

(1)

Based on 12/7°C water temperature and 30°C ambient with a 20% Ethylene Glycol Water Concentration as quoted in

Capacity Data

– DX

Mechanical Cooling

,

(2)

EER is the DX (Mechanical) Output Duty

Nominal Input.

(3)

Based on flow rate at 12/7°C water temperature and 30°C air on coil, 12°C return water temperature @ 5°C ambient with a 20% Ethylene Glycol
Water Concentration.

(4)

Based on standard unit, for units fitted with options, please contact Airedale. Machine weight includes refrigerant charge; operating weight includes
refrigerant charge and water volume.

(5)

For data on options fitted to DQ and DSQ models, please contact Airedale.