ADDITIONAL FEATURES

Security

The M2000 Security feature, when enabled, also applies to remote access (that is, HART) Refer to the M2000 IOM for

information on how to configure security

Remote reads are always allowed regardless of security rights Remote writes using the HART protocol are not allowed unless

the user has remotely logged into the meter with the appropriate access level The remote login pins are the same as the login

pins that are used on the M2000 display

Remote writes are not allowed if a user is actively navigating the menus at the display Remote login expires five minutes after

the last remote write To remotely logout more quickly, do one of the following:

Write an invalid pin to the Remote Login parameter

Send a remote logoff action request to the Service parameter

Access levels for writable parameters are defined in the Data Management section

The security status of the meter is accessible using device specific command #243 The response data is defined in the

following table:

Bit

Definition

0

If set indicates meter is secured

1

If set indicates menu access level is NONE

2

If set indicates menu access level is USER

3

If set indicates menu access level is SERVICE

4

If set indicates menu access level is ADMIN

5

If set indicates menu access level is FACTORY

6

Not Defined

7

Not Defined

8

If set indicates remote access level is NONE

9

If set indicates remote access level is USER

10

If set indicates remote access level is SERVICE

11

If set indicates remote access level is ADMIN

12

If set indicates remote access level is FACTORY

13

Not Defined

14

Not Defined

15

Not Defined

M-Series® M2000 HART® Bi-Directional Communication Protocol Data Access