Badger Meter M-Series M2000 User Manual

Page 19

Advertising
background image

Measurements

No.:

Write Security

Register Name

Register Type

HART Command Support

(DS = Device Specific

UN = Universal)

81

FIRMWARE

T1 / T+ [m

3

]

FLOAT32

UN 9 (Read)

82

FIRMWARE

T1 / T+ [User Units]

FLOAT32

UN 3/9 (Read)

83

FIRMWARE

T2 / T- [m

3

]

FLOAT32

UN 9 (Read)

84

FIRMWARE

T2 / T- [User Units]

FLOAT32

UN 3/9 (Read)

85

FIRMWARE

T3 / TN [m

3

]

FLOAT32

UN 9 (Read)

86

FIRMWARE

T3 / TN [User Units]

FLOAT32

UN 3/9 (Read)

87

FIRMWARE

T1 / T+ Rollover Counter

UINT16

DS 239 (Read)

88

FIRMWARE

T2 / T- Rollover Counter

UINT16

DS 239 (Read)

89

FIRMWARE

Flow Velocity [m/s]

FLOAT32

UN 9 (Read)

90

FIRMWARE

Flow Rate [m

3

/s]

FLOAT32

UN 9 (Read)

91

FIRMWARE

Flow Rate [User Units]

FLOAT32

UN 1/3/9 (Read)

92

FIRMWARE

Relative Flow Rate [ % ]

FLOAT32

UN 2/9 (Read)

93

FIRMWARE

Preset Batch Totalizer [m

3

]

FLOAT32

UN 9 (Read)

94

FIRMWARE

Preset Batch Totalizer [User Units]

FLOAT32

UN 9 (Read)

95

FIRMWARE

Flow Direction

UINT16

DS 239 (Read)

Meter Diagnostic Counters

No.:

Write Security

Register Name

Register Type

HART Command Support

(DS = Device Specific

UN = Universal)

96

FIRMWARE

Power Up Counter

UINT16

DS 222 (Read)

97

FIRMWARE

Detector Error Counter

UINT16

DS 222 (Read)

98

FIRMWARE

Empty Pipe Counter

UINT16

DS 222 (Read)

99

FIRMWARE

Full Scale Counter

UINT16

DS 222 (Read)

100

FIRMWARE

Totalizer Overflow Counter

UINT16

DS 222 (Read)

101

FIRMWARE

Pulse Sync Counter

UINT16

DS 222 (Read)

102

FIRMWARE

ADC Interrupt Counter

UINT16

DS 222 (Read)

103

FIRMWARE

ADC Range Counter

UINT16

DS 222 (Read)

104

FIRMWARE

WDT Resets Counter

UINT16

DS 222 (Read)

105

FIRMWARE

WDT Location

UINT16

DS 222 (Read)

106

FIRMWARE

System Error #

UINT16

DS 222 (Read)

107

FIRMWARE

Meter Status

UINT16

UN 48 (Read)

108

FIRMWARE

Action Request Overflows

UINT16

DS 222 (Read)

109

FIRMWARE

Measurement Overflows

UINT16

DS 222 (Read)

110

FIRMWARE

Remote Resets

UINT16

DS 222 (Read)

Miscellaneous

No.:

Write Security

Register Name

Register Type

HART Command Support

(DS = Device Specific

UN = Universal)

111

FIRMWARE

Power Loss Totalizer [ seconds ]

UINT32

UN 9 (Read)

112

USER

Display Backlight Mode

UINT16

DS 225/226 (Read/Write)

113

SERVICE

Preset Batch Amount [m

3

]

FLOAT32

DS 227/228 (Read/Write)

114

USER

Menu Language Setting

UINT16

DS 229/230 (Read/Write)

115

NONE

Port B Extended Address

UINT16

UN 6/7 (Read/Write)

Installation & Operation Manual

Page 19

December 2012