Output #3

No.:

Write Security

Register Name

Register Type

HART Command Support

(DS = Device Specific

UN = Universal)

52

SERVICE

Output #3:Full Scale Frequency [Hz]

UINT16

DS 212/213 (Read/Write)

53

SERVICE

Output #3: Flow Alarm Minimum [%]

UINT16

DS 204/205 (Read/Write)

54

SERVICE

Output #3: Flow Alarm Maximum [%]

UINT16

DS 206/207 (Read/Write)

55

SERVICE

Output #3: Output Mode

UINT16

DS 208/209 (Read/Write)

56

SERVICE

Output #3: Hardware Select

UINT16

DS 214/215 (Read/Write)

57

SERVICE

Output #3: Output Operation

UINT16

DS 210/211 (Read/Write)

Output #4

No.:

Write Security

Register Name

Register Type

HART Command Support

(DS = Device Specific

UN = Universal)

58

SERVICE

Output #4: Flow Alarm Minimum [%]

UINT16

DS 204/205 (Read/Write)

59

SERVICE

Output #4: Flow Alarm Maximum [%]

UINT16

DS 206/207 (Read/Write)

60

SERVICE

Output #4: Output Mode

UINT16

DS 208/209 Read/Write)

61

SERVICE

Output #4: Hardware Select

UINT16

DS 214/215 Read/Write)

62

SERVICE

Output #4: Output Operation

UINT16

DS 210/211 Read/Write)

Port A Diagnostic Counters

No.:

Write Security

Register Name

Register Type

HART Command Support

(DS = Device Specific

UN = Universal)

63

FIRMWARE

Port A: Packets Processed

UINT16

DS 220 (Read)

64

FIRMWARE

Port A: Broadcast Packets

UINT16

DS 220 (Read)

65

FIRMWARE

Port A: CRC Errors

UINT16

DS 220 (Read)

66

FIRMWARE

Port A: Packets Received

UINT16

DS 220 (Read)

67

FIRMWARE

Port A: Packets Sent

UINT16

DS 220 (Read)

68

FIRMWARE

Port A: Parity Errors

UINT16

DS 220 (Read)

69

FIRMWARE

Port A: Framing Errors

UINT16

DS 220 (Read)

70

FIRMWARE

Port A: Overrun Errors

UINT16

DS 220 (Read)

71

FIRMWARE

Port A: Break Detects

UINT16

DS 220 (Read)

Port B Diagnostic Counters

No.:

Write Security

Register Name

Register Type

HART Command Support

(DS = Device Specific

UN = Universal)

72

FIRMWARE

Port B: Packets Processed

UINT16

DS 221 (Read)

73

FIRMWARE

Port B: Broadcast Packets

UINT16

DS 221 (Read)

74

FIRMWARE

Port B: CRC Errors

UINT16

DS 221 (Read)

75

FIRMWARE

Port B: Packets Received

UINT16

DS 221 (Read)

76

FIRMWARE

Port B: Packets Sent

UINT16

DS 221 (Read)

77

FIRMWARE

Port B: Parity Errors

UINT16

DS 221 (Read)

78

FIRMWARE

Port B: Framing Errors

UINT16

DS 221 (Read)

79

FIRMWARE

Port B: Overrun Errors

UINT16

DS 221 (Read)

80

FIRMWARE

Port B: Break Detects

UINT16

DS 221 (Read)

M-Series® M2000 HART® Bi-Directional Communication Protocol Data Access