Form #04-VAM-UM-00229 09/12

Wiring Configurations

Load will turn ON when flow exceeds setpoint.

Load will turn OFF when flow exceeds setpoint.

BLACK

Flow-Alert

WHITE

Po

w

er Line

Po

w

er Line

Load

RED

Flow-Alert

WHITE

Po

w

er Line

Po

w

er Line

Load

FIGURE 7 - wIRING CoNFIGURAtIoN

FoR loADS wItHIN

Flow-AlERt CoNtACt RAtINGS

BLACK

Flow-Alert

WHITE

R

1

Load

Relay

Coil

R1

Po

w

er Line

Po

w

er Line

BLACK

Flow-Alert

WHITE

R

1

Load

Relay

Coil

R1

Po

w

er Line

Po

w

er Line

Load will turn OFF when flow exceeds setpoint.

Load will turn ON when flow exceeds setpoint.

FIGURE 8 - wIRING

CoNFIGURAtIoN FoR loADS tHAt

EXCEED Flow-AlERt

CoNtACt RAtINGS

IV - OPERATION

NotE: Refer to the Appendix for appli-

cation information and fluid charts.

MICRO SWITCH ADJUSTMENT

1. Remove cover screws and

front cover.

NotE: On meters equipped with dual

micro switches, the right-side is the

decreasing flow switch; the left-side is

the increasing flow switch.

2. Loosen the screws securing

the switching roller and

latching rollers to the guide

bar. Turn each screw one full

turn maximum.

3. All rollers are secured as a set

to the spacer strip. Slide the

entire roller set until pointer is

at the desired setting.

NotE: The spacer strip controls the

maximum distance between rollers.

This distance may be shortened when

the switching setting is close to the end

of the flow scale. Latching rollers may

also be removed if the switching set-

ting is close to the end of the flow scale.

4. Make sure roller brackets are

flush against the guide bar.

Tighten roller screws.

5. For dual switch models,

repeat steps 1-4 for left-side

switch setting.