A 4-pin Brad Harrison® quick-

disconnect plug is available upon

special order.

4-Pin Connector used with

SPDT Micro Switch

Red

Normally Closed (NC)

Black

Normally Open (NO)

White

Common

Green

Ground

tABlE 3 - 4-PIN CoNNECtoR

MICRo SwItCH

wIRE DESIGNAtIoNS

NotE: If the factory supplied cable

is removed for hard wiring the meter,

switches must be connected with

0.187” × 0.020” insulated flag termi-

nals designed for the appropriate wire

gauge for the application.

REED SWITCH MODELS

Safe operation of the reed switch is

dependent on not exceeding the

maximum wattage for that switch.

For example the normally open

reed switch has a maximum power

rating of 10 Watts. If the switch is

to operate at 24 VDC the maximum

current is found by dividing the

wattage by the voltage.

I =

W

E

=

10

24

= 0.417A

All meters (size ¼” to 1½”) are

offered in single (1) switch or

double (2) switch models and come

equipped with a 4-pin Hirschmann

connector. All units are quipped

with a 15’ length of 4-wire #22 AWG

type PVC jacketed cable.

4-Pin Connector used with

SPST Reed Switch

Red

Switch 1 Contact

Black

Switch 1 Contact

White

Optional Switch 2 Contact

Green

Optional Switch 2 Contact

tABlE 4 - 4-PIN CoNNECtoR

REED SwItCH

wIRE DESIGNAtIoNS

ALL MODELS

The strain relief connection on the

outside of the enclosure is water-

tight. Be sure to consult local wiring

codes before applying power. Some

installations will require rigid con-

duit. By removing the black strain

relief connections from the outside

of the enclosure, a conduit connec-

tion is accessible.