V. maintenance, Warning – Badger Meter Flow-Alert Reed Switch User Manual

Page 12

Advertising
background image

Page 12

Form #04-VAM-UM-00229 09/12

GPM

LPM

OIL

Screw

Arrow Pointers

on Switch Band

FIGURE 11 - REED SwItCH

ADJUStMENt - ¼” MoDElS

GPM

LPM

OIL

Arrow

Pointer

Screw

FIGURE 12 - REED SwItCH

ADJUStMENt FoR

¼” - 1½” MoDElS

(DUAl SwItCH SHowN)

V. MAINTENANCE

WARNING

Warning - Disconnect electri-

cal power before removing me-

ter cover. Failure to follow these

instructions could result in serious

personal injury or death and/or

damage to the equipment.

SWITCH REPLACEMENT

Micro Switch (Figure 13)

1. Disconnect cable connection

to the meter.

2. Remove screws securing cover

and remove cover.

3. Note the positions of the

colored wire connections on

the switch. Disconnect the

wires from the switch.

4. Remove the two mounting

bracket screws at the bottom

of the meter.

5. Remove mounting

bracket/switch assembly

from the meter. Remove the

two screws securing switch to

mounting bracket.

6. Install new switch to mounting

bracket using screws removed

in step 5.

7. Install wires to terminals on

switch as marked in step 3.

8. Install mounting bracket/

switch assembly to meter

using screws removed in step

4.

9. Install the front cover and

Advertising