6. Install the cover gasket and

front cover and secure with

screws. To properly seat the

cover gasket, tighten cover

screws in a crisscross pattern

as show in Figure 10.

LPM

Latching Roller

Spacer Strip

Switching Roller

Latching Roller

Pointer

Guide Bar

FIGURE 9 - SNAP SwItCH

ADJUStMENt

FLOW-ALERT

FLOW SWITCH

6000 PSI / 414 BARS MAX

G

PM

LPM

OIL

1

2

3

4

FIGURE 10 - CoVER SCREw

tIGHtENING SEQUENCE

Reed Switch Adjustment for ¼”

Models

1. Loosen the screw securing

the switch assembly (Figure

11).

2. Slide the switch assembly

until the arrow pointers on

the switch band are aligned

with the desired flow rate

indicated on the scale.

3. Tighten the screw.

Reed Switch Adjustment for ¼” to

1½” Models

1. Remove cover screws and front

cover.

2. Loosen the screw securing the

switch assembly (Figure 12).

NotE: On meters equipped with dual

switches, the right-side is the decreas-

ing flow switch; the left-side is the

increasing flow switch.

3. Slide the switch assembly until

the arrow pointer aligns with

the desired flow rate indicated

on the scale.

4. Tighten the screw.

5. For dual switch models, repeat

steps 1-4 for left-side setting.

6. Install the front cover and gas-

ket. To properly seat the cover

gasket, tighten cover screws in

a crisscross pattern as shown in

Figure 10.