Fsp gr, Figure 16 - conversion chart – Badger Meter Flow-Alert Reed Switch User Manual

Page 18

Advertising
background image

Page 18

Form #04-VAM-UM-00229 09/12

DETERMINE FLOW RATES USING DIFFERENT PRESSURES & TEMPERATURES

scfm actual

scfm indicated

f x f x f

(

)

(

)

=

1

3

2

Where f

1

= Conversion Factor for Inlet Pressure

f

2

= Conversion Factor for Inlet Pressure

f

3

= Conversion Factor for Inlet Pressure

Table 1 - Pressure Correction Factor (f

1

) Operating Pressure

psig

25

50

75

100

125

150

175

200

225

250

BAR

1.7

3.5

5.2

6.9

8.6

10.4

12.1

13.8

15.5

17.2

kPa

172

345

517

689

862

1034

1207

1379

1551

1724

f

1

1.700 1.331 1.131

1.00

.902

.835

.778

.731

.692

.658

f

kPa

1

790 857

101 357

=

+

.

.

f

BAR

1

7 914

1 014

=

+

.

.

f

psig

1

114 7

14 7

=

+

.

.

Table 2 - Temperature Correction Factor (f

2

)

ºF

+10

+30

+50

+70

+90

+110

+130

+150

+170

+190

°C

-12.2

-1.1

+9.9

+21.0 +32.1

+43

+54

+65

+76

+88

F

2

.942

.962

.981

1.00

1.018 1.037 1.055 1.072 1.090 1.107

f

F

2

460

530

=

+ °

f

C

2

273

293

=

+ °

Table 3 - Specific Gravity Correction Factor (f

3

)

f

Sp Gr

3

=

. .

FIGURE 16 - CoNVERSIoN CHARt

Advertising
This manual is related to the following products: