Accuracies, Ranges, and Resolutions

PSI

bar

kPa/MPa kg/cm2 Overpressure

PSI

kg/cm2

inHg

inH20

*

mmHg mmH20

kPa

bar

mbar

MPa

30PSI

 

 

 

3.0 x

0.001

0.0001

0.001

0.01

0.01

1

0.01

0.0001

0.1

 

 

3BAR

 

 

3.0 x

0.001

0.0001

0.001

0.01

0.01

1

0.01

0.0001

0.1

 

 

 

300KPA

 

3.0 x

 

 

 

 

 

 

0.01

0.0001

0.1

 

 

 

 

3KG

3.0 x

0.001

0.0001

0.001

0.01

0.01

1

0.01

0.0001

0.1

 

100PSI

 

 

 

2.0 x

0.001

0.0001

0.01

0.1

0.1

1

0.01

0.0001

0.1

0.00001

 

10BAR

 

 

2.0 x

0.001

0.0001

0.01

0.1

0.1

1

0.01

0.0001

0.1

0.00001

 

1MPA

 

2.0 x

 

 

 

 

 

 

0.01

0.0001

0.1

0.00001

 

 

 

10KG

2.0 x

0.001

0.0001

0.01

0.1

0.1

1

0.01

0.0001

0.1

0.00001

300PSI

 

 

 

2.0 x

0.01

0.001

0.01

0.1

0.1

 

0.1

0.001

1

0.0001

 

30BAR

 

 

2.0 x

0.01

0.001

0.01

0.1

0.1

 

0.1

0.001

1

0.0001

 

 

3MPA

 

2.0 x

 

 

 

 

 

 

0.1

0.001

1

0.0001

 

 

 

30KG

2.0 x

0.01

0.001

0.01

0.1

0.1

 

0.1

0.001

1

0.0001

1KPSI

 

 

 

2.0 x

0.1

0.001

0.1

 

 

 

0.1

0.001

 

0.0001

 

100BAR

 

 

2.0 x

0.1

0.001

0.1

 

 

 

0.1

0.001

 

0.0001

 

 

10MPA

 

2.0 x

 

 

 

 

 

 

0.1

0.001

 

0.0001

 

 

 

100KG

2.0 x

0.1

0.001

0.1

 

 

 

0.1

0.001

 

0.0001

3KPSI

 

 

 

1.5 x

0.1

0.01

0.1

 

 

 

1

0.01

 

0.001

 

300BAR

 

 

1.5 x

0.1

0.01

0.1

 

 

 

1

0.01

 

0.001

 

 

30MPA

 

1.5 x

 

 

 

 

 

 

1

0.01

 

0.001

 

 

 

300KG

1.5 x

0.1

0.01

0.1

 

 

 

1

0.01

 

0.001

10KPSI

 

 

 

1.5 x

1

0.01

 

 

 

 

1

0.01

 

0.001

 

700BAR

 

 

1.5 x

1

0.01

 

 

 

 

1

0.01

 

0.001

 

 

70MPA

 

1.5 x

 

 

 

 

 

 

1

0.01

 

0.001

 

 

 

700KG

1.5 x

1

0.01

 

 

 

 

1

0.01

 

0.001

15KPSI

 

 

 

1.3 x

1

0.01

 

 

 

 

1

0.01

 

0.001

 

1000BAR

 

 

1.3 x

1

0.01

 

 

 

 

1

0.01

 

0.001

 

 

100MPA

 

1.3 x

 

 

 

 

 

 

1

0.01

 

0.001

 

 

 

1000KG

1.3 x

1

0.01

 

 

 

 

1

0.01

 

0.001

*

Density of water can be set to 4°C, 60°F or 20°C /68°F with CrystalControl software .

0.025%

of Reading

modules

0.05%

of Reading

modules

0.1%

of Reading

modules

Reference Recorder Numbering System

Product ID

Power

Upper Chassis

Module

Lower Chassis

Module

BARO Module

(Optional)

NV

4AA

PM

PM

No: (omit)

MA20

MA20

Yes: BARO

RTD100

RTD100

Lab Reference Numbering System

Product ID

Power

Upper Chassis

Module

Lower Chassis

Module

BARO Module

(Optional)

NL

LAB

PM

PM

No: (omit)

MA20

MA20

Yes: BARO

RTD100

RTD100

Sample Part Numbers

NL-LAB-30PSI-1KPSI

NL-LAB-MA20-3KPSI-BARO

Sample Part Numbers

NV-4AA-30PSI-3KPSI-BARO

NV-4AA-RTD100-10KPSI