3 configuration in the bus system 3.3.1 – NORD Drivesystems BU0570 User Manual

Page 15

Advertising
background image

3 Commissioning

BU 0570 GB-0312

Subject to technical amendments

15

3.3 Configuration in the Bus system

3.3.1

Integration into TwinCAT System Manager (Example)

In the following, the integration of the SK TU3-ECT into the Beckhoff TwinCAT System Manager will be
explained. All modules must be connected and supplied with power.

 Reboot of TwinCAT in config. mode via

or Shift + F4.

 Scan the EtherCAT bus for connected units. See following diagram.

Fig. 7 Scanning the EtherCAT bus

 The SK TU3-ECT modules which are found will be listed in the structural diagram
 If an FI is to by parameterised with POSICIN or SERVO functionality via the System Manager, the

scanned type must be changed (Change to Alternative Type): see the following diagram. An
extended XML file containing the additional parameters will then be loaded. This step only needs to
be carried out once.

Fig. 8 Calling up the function "Change to Alternative Type"

 With this, the SK TU3-ECT units are then integrated