4.2.5

Setpoint and actual values

The meanings of setpoints are defined via the FI parameters P546 to P548 (SK 540E and above:
P546[-01] … [-05]). For the actual values, this determination is made via the FI parameters P543 to P545
(SK 540E and above: P543[-01] … [-05]).
The transfer of setpoint and actual values is carried out by three different methods, which will be explained
below.

Percentage transfer
The process value is transferred as a whole number with a value range of -32768 to 32767 (8000 hex to
7FFF hex). The value 16384 (4000 hex) is equal to 100%. The value -16384 (C000 hex) is equal to -100%.
For frequencies, the 100% value corresponds to the FI parameter "Maximum Frequency" (P105) and for
currents, this is the FI parameter "Torque Current Limit" (P112) Frequencies and currents result from the
following formulae.

16384

105

P

Value

Frequency

16384

112

P

Value

Current

Value = the 16Bit actual or setpoint value transmitted via Ethernet

Formula 1 Formation of 16Bit setpoint/actual value

Binary transmission
Inputs and outputs as well as Digital In bits and Bus Out bits are evaluated for each bit.

Transmission of positions
In the FI, positions have a value range of +/- 50000,000 rotations. A motor rotation can be divided into a
maximum of 1000 steps. This scaling is independent of the encoder which is used.
The 32Bit value range is divided into a Low and a High word, so that 2 setpoint/actual values are required
for transmission.

Direction of

transmission

Transmitted data (8 Byte)

1.

word

2. word

3. word

4. word

... to SK TU3-

Control word

32Bit setpoint

Setpoint 3

... from the SK TU3-

Status word

Actual value 1

32Bit actual value

Table 16 Depiction of 32Bit setpoint/actual values

It is also possible to only transmit the Low component of the position. This results in a limited value range
from +32,767 to -32,768 rotations. This value range can be extended with the aid of the gear ratio factor