HP StorageWorks MSA 2.8 SAN Switch User Manual
Page 178

Diagnostics and Status
178
Fabric OS Procedures Version 3.1.x/4.1.x User Guide
.
For more information, refer to the
switchshow
command in the HP
StorageWorks Fabric OS Version 3.1.x/4.1.x Reference Guide.
The following example shows the
switchshow
command output on a Core
Switch 2/64.
Example
port 0: id N1 Online E-Port 10:00:00:60:69:11:fc:08 "fmgr129"
(downstream
)
port 1: id N2 Online E-Port 10:00:00:60:69:90:03:1f "fmgr137"
(upstream)
port 2: -- N2 No_Module
port 3: -- N2 No_Module
port 4: -- N2 No_Module
port 5: -- N2 No_Module
port 6: id N2 No_Light
port 7: id N2 No_Light
switch:admin>
switch:admin> switchshow
switchName: switch61
switchType: 10.1
switchState: Offline
switchRole: Disabled
switchDomain: 97 (unconfirmed)
switchId: fffc61
switchWwn: 10:00:00:60:69:80:04:5a
switchBeacon: OFF
blade1 Beacon: OFF
blade3 Beacon: OFF
Area Slot Port Gbic Speed State
=====================================
0 1 0 id N2 No_Light Disabled