Specific scenarios, Host can not see target (storage or tape devices), Check the logical connection – HP StorageWorks MSA 2.8 SAN Switch User Manual
Page 199
 
Troubleshooting
199
Fabric OS Procedures Version 3.1.x/4.1.x User Guide
Specific Scenarios
The following sections provide specific help with some of the most common SAN 
problems. 
Host Can Not See Target (Storage or Tape Devices)
When a host cannot “see” its disks, the best way to troubleshoot the problem is to 
start in the middle half of the data path, figure out if the problem is “above” or 
“below” the data path, and keep dividing the suspect path in half until the problem 
is identified.
There are two areas to check in the process of elimination:
■
■
Check the Simple Name Server (SNS)
■
Check for Zoning Discrepancies
■
Check Device Communication
Check the Logical Connection
Check Whether the Device is Logically Connected to the Switch
1. Enter the
switchShow
command.
2. Review the output and determine if the device is logically connected to the
switch:
— A device that is logically connected to the switch will be registered as an
NX_Port.
— A device that is not logically connected to the switch will be registered as
something besides an NX_Port.
— If the missing device is logically connected, move on to
.
— If the missing device is not logically connected, eliminate the host
and everything on that side of the data path from the suspect list. 
This includes all aspects of the host’s OS, the HBA driver settings and 
binaries, the HBA Basic Input Output System (BIOS) settings, the 
HBA SFP, the cable going from the switch to the host, the SFP on the 
switch side of that cable, and all switch settings related to the host. 
Move on to