Troubleshooting
233
Fabric OS Procedures Version 3.1.x/4.1.x User Guide
E_port
If the opposite side is not another switch, the link has come up in a
wrong mode. Check the output from the
portLogShow
/
PortLogDump
commands and identify the link
initialization stage where the initialization procedure went wrong.
F_port
If the opposite side of the link is a fabric device, the link has come
up in a wrong mode. Check the output from the
portLogShow
or
PortLogDump
commands.
G_port
The port has not come up as an E_port or F_port. Check the output
from the
portLogShow
or
PortLogDump
commands and
identify the link initialization stage where the initialization
procedure went wrong.
L_port
If the opposite side is
not
a loop device, the link has come up in a
wrong mode. Check the output from the
portLogShow
or
PortLogDump
commands and identify the link initialization stage
where the initialization procedure went wrong.
Table 21: SwitchShow Output and Suggested Action (Continued)
Output
Suggested Action