HP XP Data Shredder Software User Manual

Page 43

Advertising
background image

Description

Item

Select the unit to use for specifying the capacity of the VLL
volume:

MB: Megabytes. This unit is used for specifying the
capacity of open-system volumes.

Cyl: Cylinders. This unit is used for specifying the
capacity of mainframe volumes. This unit can also be
used for specifying the capacity of OPEN-V volumes.

Block: Blocks. This unit is used for specifying the
capacity of external volumes. For details regarding
external volumes, see the HP StorageWorks
XP24000/XP20000 External Storage Software User
Guide
.

Capacity Unit

Select to specify the capacity and the number of CVs in
the VLL volume that you want to create.

Use the Capacity field to enter the capacity of the VLL
volume in the unit selected in the Capacity Unit list. The
available capacity range (minimum - maximum) is shown
underneath (for example, 46 - 6720 MB, 50 - 7168 Cyl,
or 315 - 8513 blocks).

Use the No. field to enter the number of volumes of that
size. The available range is shown on the right side of the
box (for example, 1 - 489).

When Capacity Unit is MB or Cyl, there might be a
difference of up to several hundred kilobytes between the
entered CV capacity and the resulting CV capacity.

Specify capacity and number

Select to create VLL volumes by specifying the number of
CVs in the VLL volume to be created. This option can be
selected only when the emulation type is OPEN-V.

When this option is selected, the available range (for
example, 1 - 47) appears on the right side of the box.

Use the No. field to enter the number of CVs in the VLL
volume.

When Capacity Unit is MB or Cyl, the capacity of each CV
will not be exactly the same as when Capacity Unit is Block,
and vice versa.

Divide free space by number

Select to create VLL volumes by specifying the capacity of
CVs in the VLL volume to be created. This option can be
selected only when the emulation type is OPEN-V.

Use the Capacity field to enter the capacity of the VLL
volumes to be created. The available capacity range
(minimum - maximum) is shown under the Capacity field
(for example, 46 - 6720 MB, 50 - 7168 Cyl, or 315 -
8513 blocks).

When Capacity Unit is MB or Cyl, there might be a
difference of up to several hundred kilobytes between the
entered CV capacity and the resulting CV capacity.

Divide free space by capacity

Select to create a VLL volume using the remaining space
in the VDEV. This option is available only when the
emulation type is OPEN-V. This option is unavailable when
there are two or more free spaces in the VDEV.

Set remaining space as volume

Opens the selected settings in the LDEV information table
on the left.

Set

Deletes the settings from the VLL volume that is selected in
the LDEV information table.

Delete

Make Volume Dialog Box (1)

43

Advertising
This manual is related to the following products: