For example, in – HP XP Racks User Manual

Page 35

Advertising
background image

controller of an LU is CHA0, and access to the LU is made via only one path

(A). After that access path (A) is placed offline, the first choice for the

switching destination is the other path connected to CHA0 (B). If an error

also occurs on that path (B), then the next possibility for a path comes from

one of the two paths (C or D) connected to CHA1.

When the Lightning 9900V series, Hitachi USP series, Universal Storage

Platform V/VM series, Virtual Storage Platform series, Hitachi AMS2000
series

#

, Hitachi SMS series, or HUS100 series

#

is being used, all the paths

are owner paths. This means all the paths accessing the same LU can be

possible switching destinations. For example, in

Figure 2-8 Path switching on

page 2-15

, the LU is accessed using only the path (A). After the access path

is placed offline, the switching destination is one of the paths (B), (C), and

(D).

#

This storage system applies when the dynamic I/O path control function is

disabled.

For details on the priority for determining which of the paths to the same LU

is used as the switching destination, see

Priority of Switching Destination

Paths on page 2-16

.

Figure 2-8 Path switching

HDLM Functions

2-15

Hitachi Dynamic Link Manager User Guide for AIX®

Advertising
This manual is related to the following products: