HP Integrity NonStop H-Series User Manual

Page 59

Advertising
background image

Troubleshooting

9840 (CT9840FC-3) Installation and User’s Guide for the NonStop S-Series Enclosure524959-003

A- 5

Operator Panel Messages

DumpAgain?

Drive detected the same CHK
(FSC) within one minute.

Go to “‘Handling a Dump Again?’
Indication” in Appendix A.

“Exp ClCart”

Cleaning cartridge is used up.

Replace the cleaning cartridge.

FFFF:Dmp Y

Alternates with corporate ID at
completion of IPL, where
FFFF=FSC of last dump date
collected, Y=number of
uncollected dumps in EEPROM.

Optionally move dump/s to host
or tape: see various dump
instructions in section 5 or 7.

Fix_CfgErr

Upon IPL, configuration
checksum doesn’t match.

Go to “What to do if the Fix
CfgErr Occurs” in Appendix A.

INIT (FSC)

Initialization error.

Try IPL: if that fails, replace drive.

IPL Pend

IPL Pending is displayed for one
second when IPL is pressed.

Wait until IPL completes
automatically.

Load CC

The common controller code is
loading.

No user action is necessary.

Loading

Tape cartridge is being loaded.

No user action is necessary.

Load ESCON

Normal display during boot.

Wait for IPL to complete.

Load (FSC)

Load/unload operation has failed.

If another tape also fails load, IPL
drive. If failure persists, replace
drive. If another tape works, tape
is suspect.

Load SCSI

Normal display during boot.

Wait for IPL to complete.

Locating

Drive is doing a high speed seek.

No user action is necessary.

Memory Err

RAM failed during IPL.

IPL again. If that fails, replace
drive.

NT Ready F

Non-write protected tape is in
process of manual unload.

Wait until unload operation
completes.

NT Ready U

Write protected tape is in process
of manual unload.

Wait until operation completes.

Online

The drive is operational.

No user action is necessary.

Power Fail

Power supply has failed.

Replace power supply.

Reading

The drive is in the read mode.

No user action is necessary.

Ready F

Loaded tape is file protected.

Operator discretion.

Ready U

Loaded tape is not file protected.

Operator discretion.

Rewinding

The drive is rewinding.

No user action is necessary.

Save Fails

New configuration cannot be
saved.

Replace drive.

Table A-1. Operator Panel Displays

Display

Probable Cause

Recommended Action

Advertising