Canceling the Cross-subsystem Path Configuration

You can cancel the configuration of the cross-subsystem path using the Configure Cross-subsystem Paths

dialog box.
To cancel the cross-subsystem path configuration:

1.

Start Remote Web Console, and open the Volume Operation window.

2.

Make sure that Remote Web Console is in Modify mode.

3.

Click the path group to which the cross-subsystem path belongs in the Volume Operation tree.

4.

Right-click the cross-subsystem path in Cross-subsystem Paths in the Volume Operation list.

A pop-up menu is displayed.

5.

Click Configure Cross-subsystem Paths in the pop-up menu.

The Configure Cross-subsystem Paths dialog box is displayed (see

Configure Cross-subsystem Paths Dialog Box

” on page 78).

6.

Right-click the cross-subsystem path that you want to cancel the configuration in the Selected

Paths in the Configure Cross-subsystem Paths dialog box.

A pop-up menu is displayed.

7.

Click Delete in the pop-up menu

The configuration of the selected cross-subsystem path is canceled, and the cross-subsystem path

is deleted from the Cross-subsystem Paths.

8.

Click OK to close the Configure Cross-subsystem Paths dialog box.

You are returned to the Volume Operation window. The settings are displayed in blue and italics.

9.

Verify the settings in the Preview dialog box (see “

Preview Dialog Box

” on page 57).

10.

Click Apply in the Volume Operation window.

The settings are applied to the local storage system and the Volume Operation window is

displayed normally. When an error occurs, an error message is displayed. Verify the details

in the Preview dialog box.

Changing the Cross-subsystem Path

To change the cross-subsystem path, cancel the current cross-subsystem path, and configure another

cross-subsystem path as a new cross-subsystem path. For how to cancel the current cross-subsystem

path, see

Canceling the Cross-subsystem Path Configuration

” on page 83 For how to configure an

cross-subsystem path, see

Configuring Cross-subsystem Path

” on page 81.

Checking the External Volume Details

You can check the details on the mapped external volume using the LDEV Information dialog box, and

the details on the mapping path using the Mapping Path Information dialog box.
To check the external volume details:

1.

Start Remote Web Console, and open the Volume Operation window.

2.

Click the path group in the Volume Operation tree.

3.

Right-click the external volume that you want to check in the Volume Operation list.

A pop-up menu is displayed.

4.

Click the following command in the pop-up menu.
• LDEV information: Displays the LDEV Information dialog box (section

LDEV Information Dialog Box

” on page 84).

• Mapping Path Information: Displays the Mapping Path Information dialog box (section

Mapping Path Information Dialog Box

” on page 84).

5.

Verify the details in the displayed dialog box.

6.

Click Close to close the displayed dialog box.

You are returned to the Volume Operation window.

XP24000 External Storage Software User’s Guide

83

Advertising
This manual is related to the following products: