Preview dialog box, 8 pop-up, Menu – HP XP External Storage Software User Manual

Page 57: External, Volumes, Volume, Operation, Window)

Advertising
background image

Table 8 Pop-up Menu in the External Volumes (Volume Operation Window)

Pop-up menu

Reference

Description

Mapping Path

Information

Section

Checking

the External Volume

Details

on page 83.

Displays the Mapping Path Information dialog box. This

dialog box allows you to see the list of the mapping

paths set to the selected external volume.

LDEV Information

Displays the LDEV Information dialog box. This dialog

box allows you to see the emulation type and the

capacity of the selected external volume.

Delete Volume

Section

Deleting

the External Volume

Mapping

on page

96.

Cancels the mapping of the selected external volume.

Disconnect Volume

Section

Disconnecting an

Individual External

Volume (Disconnect

Volume)

on page

90.

Disconnects the selected external volume.

Check Paths & Restore

Volume

Section

Checking

Connection Status

and Resuming

External Volume

Operation

on page

(p. 91).

Reconnects the selected external volume.

Change Cache Mode

Section

Changing

the Cache Mode

Setting of the

External Volume

on page 93.

Changes the cache mode set to the selected external

volume.

Inflow Control

Section

Changing

the Inflow Control

Setting of the

External Volume

on page 94.

Allows you to select whether to stop writing to the

cache memory when it is impossible to write to the

selected external volume.

Right-click a row in the Cross-subsystem Paths (at the bottom of the window) to perform the

following operations from the pop-up menu.

Table 9 Pop-up Menu in the Cross-subsystem Paths (Volume Operation Window)

Pop-up menu

Reference

Description

Configure Cross-

subsystem Paths

Section

Configure

Cross-subsystem

Paths Dialog Box

on page 78.

Displays the Configure Cross-subsystem Paths dialog

box. This dialog box allows you to add and delete

cross-subsystem paths, and also change the priority of

the selected cross-subsystem path.

Preview Dialog Box

The Preview dialog box allows you to check or cancel the settings that will be applied to the local storage

system. To display the Preview dialog box, click Preview in the Volume Operation window, the Path

Operation window, or the Port Operation window. This document uses the term the External Storage

windows to call these three windows.
The contents displayed in the Preview dialog box are displayed in blue and italics in the list of the External

Storage windows. The contents displayed in the Preview dialog box have not been applied to the local

storage system, yet. When you click Apply on the External Storage windows, the settings in the Preview

dialog box are applied to the local storage system. When the settings are applied, the contents of the

XP24000 External Storage Software User’s Guide

57

Advertising
This manual is related to the following products: