Slot numbering and mailslot configurations

Magazine and mailslot numbering begins with the lower Library and continues with the master Library.
For storage slot numbering, see

Table 2

.

Table 2 Storage slot numbering

Slot numbers (without mailslots enabled)

Extended library configuration

Master Library

Lower Library

Master Library

Lower Library

25–72

1–24

MSL4048

MSL2024

49–96

1–48

MSL4048

MSL4048

25–120

1–24

MSL8096

MSL2024

49–144

1–48

MSL8096

MSL4048

The mailslots in both Libraries can be configured for use in the extended library. For mailslot numbering,
see

Table 3

.

Table 3 Mailslot numbering

Mailslot numbers (with all mailslots enabled)

Extended library configuration

Master Library

Lower Library

Master Library

Lower Library

M2–M4

M1

MSL4048

MSL2024

M4–M6

M1–M3

MSL4048

MSL4048

M2–M16

M1

MSL8096

MSL2024

M4–M19

M1–M3

MSL8096

MSL4048

Tape drives

Tape drives are numbered starting with the lower Library and continuing with the master Library.

Any tape drive in the extended library can host the SCSI Library interface. The default is the lowest
tape drive in the lower Library.

Power supply redundancy

Both Libraries must have a working power supply for the extended library to operate. To have total
power supply redundancy, both Libraries must have working redundant power supplies. In an extended
library, if only one Library has redundant power supplies installed, the extended library will continue
to operate in case of a power supply failure in that Library. An extended library containing an
MSL2024 cannot have total power supply redundancy because the MSL2024 only has one power
supply.