Message id – HP 3PAR Application Software Suite for Oracle User Manual

Page 189

Advertising
background image

During rmora_createdb process, the error occurs when:

A non-default clone location (option -d) was specified to clone the database, and

At least one of the clone locations is an ASM disk group, which means the control file will
reside on one of the ASM disk groups on the backup server, and

The ASM instance on the backup server does not contain the disk group for the control file.

SOLUTION
Before executing rmora_createdb, make sure the ASM instance on the backup server has the
ASM disk group that will hold control files exists and is mounted.
Symantec NetBackup is third-party software, and HP makes no representations or warranties with
respect to such software.

MESSAGE ID

1307
MESSAGE
3PAR1307: ERROR: multipathd daemon is not running.
REASON
On the backup server, Oracle asmlib configuration file (/etc/sysconfig/oracleasm, which
links to /etc/sysconfig/oracleasm-_dev_oracleasm) has “dm” specified for
ORACLEASM_SCANORDER, which means Oracle will scan the device mapper devices. However,
Recovery Manager for Oracle checks and finds out that there is no multipathd daemon running,
hence the error displayed.
SOLUTION
Start the multipathd daemon using the command /sbin/service multipathd start or
/etc/init.d/multipathd start

.

MESSAGE ID

1308
MESSAGE
3PAR1308: ERROR: Failed to tar/untar file <file> in directory <directory>.
REASON
The rmora_export command uses the tar command to create a tarball from the backup server
repository, copy the tarball, and extract it on the alternate backup server. The error occurs when
the tar command fails.
SOLUTION
Check the error message and make sure the tar command works on both the backup server and
the alternate backup server. The tar command should be in /bin/tar in Linux and /usr/bin/
tar

in HP UX and Solaris.

MESSAGE ID

1310
MESSAGE
3PAR1310: ERROR: Unable to auto-discover HP 3PAR Storage Server Host name for Host <host>.
REASON
Recovery Manager for Oracle is unable to auto-discover the corresponding TPD hostname on the
HP 3PAR storage system given the alternate hostname.
SOLUTION

189

Advertising