Operands

PhyPGU[Short|Long]U[[parity-group-id]:[parity-group-id]][U…]

Use this operand when you want to export statistics about parity group usage rates, which are

displayed in the Physical tab of the Auto LUN window. When statistics are exported to a ZIP file,

the file name will be PhyPG_dat.ZIP. For details on the statistics exported by this operand, see

Table 11

on page 74 in

Files to be Exported

” on page 73.

You can use the Short or Long option to select the storing period of the monitoring data to be

exported. If you specify Short, the exported file will contain statistics in short range for up to 15

days. If you specify Long, the exported file will contain statistics in long range for up to three

months (that is, up to 93 days). If neither Short nor Long is specified, statistics both in the short

range and long range will be exported.
When you specify variables parity-group-id, you can narrow the range of parity groups whose

monitoring data are to be exported. parity-group-id is a parity group ID. The colon (:) indicates a

range. For example, 1-1:1-5 indicates parity groups from 1-1 to 1-5.
Ensure that the parity-group-id value on the left of the colon is smaller than the parity-group-id

value on the right of the colon. For example, you can specify PhyPG 1-1:1-5, but you cannot

specify PhyPG 1-5:1-1. Also, you can specify PhyPG 1-5:2-1, but you cannot specify

PhyPG 2-1:1-5.
If parity-group-id is not specified, the monitoring data of all the parity groups will be exported.

PhyLDEVU[Short|Long]U[[parity-group-id]:[parity-group-id]][U…]

Use this operand when you want to export statistics about volume usage rates, which are

displayed in the Physical tab of the Auto LUN window. When statistics are exported to a ZIP file,

the file name will be PhyLDEV_dat.ZIP. For details on the statistics exported by this operand, see

Table 11

on page 74 in

Files to be Exported

” on page 73.

You can use the Short or Long option to select the storing period of the monitoring data to be

exported. If you specify Short, the exported file will contain statistics in short range for up to 15

days. If you specify Long, the exported file will contain statistics in long range for up to three

months (that is, up to 93 days). If neither Short nor Long is specified, statistics both in the short

range and long range will be exported.
When you specify variables parity-group-id, you can narrow the range of parity groups whose

monitoring data are to be exported. parity-group-id is a parity group ID. The colon (:) indicates a

range. For example, 1-1:1-5 indicates parity groups from 1-1 to 1-5.
Ensure that the parity-group-id value on the left of the colon is smaller than the parity-group-id

value on the right of the colon. For example, you can specify PhyLDEV 1-1:1-5, but you

cannot specify PhyLDEV 1-5:1-1. Also, you can specify PhyLDEV 1-5:2-1, but you cannot

specify PhyLDEV 2-1:1-5.
If parity-group-id is not specified, the monitoring data of all the volumes will be exported.

PhyExGU[[exg-id]:[exg-id]][U…]

Use this operand when you want to export statistics about external volume groups, which are

displayed in the Physical tab of the Auto LUN window. When statistics are exported to a ZIP file,

the file name will be PhyExG_dat.ZIP. For details on the statistics exported by this operand, see

Table 11

on page 74 in

Files to be Exported

” on page 73.

When you specify variables exg-id, you can narrow the range of external volume groups whose

monitoring data are to be exported. exg-id is an ID of an external volume group. The colon (:)

indicates a range. For example, E1-1:E1-5 indicates external volume groups from E1-1 to E1-5.
Ensure that the exg-id value on the left of the colon is smaller than the exg-id value on the right

of the colon. For example, you can specify PhyExG E1-1:E1-5, but you cannot specify

PhyExG E1-5:E1-1. Also, you can specify PhyExG E1-5:E2-1, but you cannot specify

PhyExG E2-1:E1-5.