LDKC list:

indicates LDKC numbers. To select an LDKC as a monitoring target, click the LDKC number. All

the CUs that belong to that LDKC are displayed.

CU table:

The CU table consists of cells representing CUs. Each row consists of 16 cells (CUs). A set of

16 rows represents CUs for one LDKC. The table header row displays the last digit of each CU

number in the form of +n (n is an integer between 0 and 9, or a letter from A to F).

To select a CU, click a cell to invert its color. To restore the cell to its original color, click the

inverted cell. To select all the (16) CUs of the same number in the second last digits, click the

CU number (00 to F0). By dragging the cursor over multiple cells, you can select all the cells

from the source to the destination.

For your information, one cell corresponds to one CU. The relation of the display of a cell to the

CU status is shown below:

Table 7 The Relationship between the Display of a Cell and the CU Status in the

CU Table

CU to be used or not

CU to be monitoring target or not

Letter displayed in the cell

CU which is already monitoring target

S: in black

CU to be used

CU which is going to release from

monitoring target

R: in blue italics

CU to be removed from the monitoring target None

CU not to be used

CU that is already monitoring target

N: in black

CU which is going to release from

monitoring target

-: Hyphen in black bold

CU to be removed from the monitoring

targets

-: Hyphen in black

Monitoring Target CUs:

indicates the number of existing and newly added CUs to be monitored.

The Select button adds the CU selected in the CU table to the CUs to be monitored.

Table 8 The Characters Indicated in a Cell When the Select Button is Clicked

Before Click

After Click

-: Hyphen in black

N: in black italics

R: in blue italics

S: in black

The Release button remove the CU from monitoring targets.

Table 9 The Characters Indicated in a Cell When Release Button is Clicked

Before Click

After Click

N: in black

-: Hyphen in black bold

S: in black

R: slanted in blue italics

The Apply button applies settings in the Monitoring Options window to the storage system.

The Reset button resets the settings in the Monitoring Options window.

Performance Monitor has two kinds of periods (ranges) for collecting and storing statistics: short range

and long range.
The storing period of statistics in short range is determined by the settings of Gathering Interval option.

Performance Monitor saves the statistics obtained up to 1440 times in SVP. Therefore, you can estimate

the storing period of statistics with gathering interval multiplied by 1440. For example, if you specify