group PG 1-3:

The following example exports statistics about the external volume groups E1-1 to E1-5:

group PG E1-1:E1-5

The following example exports statistics about the parity group 1-3 and other parity groups whose ID

is smaller than 1-3 (for example, 1-1 and 1-2):

group LDEV :1-3

The following example exports statistics about LU paths for the host group (host storage domain) ID

01 for the port CL1-A:

group LU CL1-A.01:CL1-A.01

shortrange Subcommand

Syntax

shortrangeU[[yyyyMMddhhmm][{+|-}hhmm]:[yyyyMMddhhmm][{+|-}hhmm]]

Description

The shortrange subcommand enables you to specify a term of monitoring data to be exported into files.

Use this subcommand when you want to narrow the export-target term within the stored data.
The shortrange subcommand is valid for monitoring data in short range. The monitoring data in short

range is the contents displayed in the following windows:

The Auto LUN window with selecting shortrange as the storing period

The Continuous Access Monitor and TrueCopy for Mainframe Monitor windows

The Continuous Access Journal Monitor and Universal Replicator for Mainframe Monitor windows

All the monitoring items are stored in short range. Therefore, you can use the shortrange subcommand

whichever operand you specify to the group subcommand. If you run the Export Tool without specifying

the shortrange subcommand, the data stored in the whole monitoring term will be exported.
The login subcommand must execute before the shortrange subcommand executes.

Operands

The value on the left of the colon (:) specifies the starting time of the period. The value on the right of the

colon specifies the ending time of the period. Specify the term within Short Range From XXX To

XXX which is output by the show subcommand.
If no value is specified on the left of the colon, the starting time for collecting monitoring data is assumed.

If no value is specified on the right of the colon, the ending time for collecting monitoring data is

assumed. The starting and ending times for collecting monitoring data are displayed in the Monitoring

Term area in the Auto LUN window (see