Operands

The value on the left of the colon (:) specifies the starting time of the period. The value on the right of the

colon specifies the ending time of the period. Specify the term within Long Range From XXX To

XXX which is output by the show subcommand.
If no value is specified on the left of the colon, the starting time for collecting monitoring data is assumed.

If no value is specified on the right of the colon, the ending time for collecting monitoring data is

assumed. The starting and ending times for collecting monitoring data are displayed in the Monitoring

Term area in the Auto LUN window (see

Figure 48

on page 115).

Figure 48 Starting and Ending Time for Collecting Monitoring Data

yyyyMMddhhmm

yyyyMMdd indicates the year, the month, and the day. hhmm indicates the hour and the minute.
If yyyyMMddhhmm is omitted on the left of the colon, the starting time for collecting monitoring

data is assumed. If yyyyMMddhhmm is omitted on the right of the colon, the ending time for

collecting monitoring data is assumed.

+ddhhmm

Adds time (ddhhmm) to yyyyMMddhhmm if yyyyMMddhhmm is specified. For example,

200601120000+010130 indicates Jan. 13, 2006. 01:30.
Adds time to the starting time for collecting monitoring data, if yyyyMMddhhmm is omitted.

-ddhhmm

Subtracts time (ddhhmm) from yyyyMMddhhmm if yyyyMMddhhmm is specified. For example,

200601120000-010130 indicates Jan. 10, 2006. 22:30.
Subtracts time from the ending time for collecting monitoring data, if yyyyMMddhhmm is omitted.

Note:

Ensure that mm is 00, 15, 30, or 45. If you do not specify mm in this way, the value on the left of

the colon (:) will be rounded down to one of the four values. Also, the value on the right of the colon will

be rounded up to one of the four values. For example, if you specify 200601010013:200601010048,

the specified value is regarded as 200601010000:200601010100.

Example

The examples below assume that:

the starting time for collecting monitoring data is Jan. 1, 2006, 00:00,

the ending time for collecting monitoring data is Jan. 2, 2006, 00:00.

longrange 200601010930:2004601011730

The Export Tool saves monitoring data within the range of Jan. 1, 9:30-17:30.

longrange 200601010930:

The Export Tool saves monitoring data within the range of Jan. 1, 9:30 to Jan. 2, 00:00.