HP XP Array Manager Software User Manual

Page 23

Advertising
background image

User types

If the user type of your user ID is storage partition administrator, the functions you can use are

limited. For details, see

Storage Partition Administrators Limitations

” on page 25.

Powering off the storage system

If you power off the storage system during monitoring, monitoring stops only while the storage

system is powered off. When you power on the storage system again, Performance Monitor

cannot display the monitoring data while the storage system is powered off. The monitoring data

immediately after powering on again might contain extremely large values.

Viewing the Physical tab
• You will be able to view usage statistics that have been obtained for the last three months (that

is, 93 days) in long-range monitoring, and for the last 15 days in short-range monitoring. You

will not be able to view usage statistics that expired after these storing periods because such

statistics are erased from the storage system.

• In short range, if I/O workloads between hosts and the storage system become heavy,

the storage system gives higher priority to I/O processing than monitoring processing,

therefore, a part of monitoring data might be missing. In case that monitoring data are

missing frequently, use the Gathering Interval option in the Monitoring Options window to

change the collection interval longer. For details, see

Start Monitoring

” on page 47 and

Monitoring Options Window

” on page 42.

• Short-range monitoring data and long-range monitoring data may have some margin of error.

Viewing the LDEV, Port-LUN, and WWN tab
• Monitoring results are stored for the last 8 hours to 15 days depending on the specified

gathering interval. If the storing period have passed since a monitoring result was obtained,

the result is erased from the storage system and you will not be able to view that monitoring

result.

• If I/O workloads between hosts and the storage system become heavy, the storage system gives

higher priority to I/O processing than monitoring processing, therefore, a part of monitoring

data might be missing. In case that monitoring data are missing frequently, use the Gathering

Interval option in the Monitoring Options window to change the collection interval longer. For

details, see “

Start Monitoring

” on page 47 and “

Monitoring Options Window

” on page 42.

Displaying monitoring data
• In lists of the Auto LUN window contents, a hyphen (-) might be displayed in monitoring data

columns. It means that the statistics of that monitoring item cannot be collected.

• If the SVP is overloaded, more time than the gathering interval allots might be required for

updating the display of monitoring data. In this case, some portion of monitoring data will not

be displayed in the window. For example, suppose that the gathering interval is 1 minute.

In this case, if the display in the Auto LUN window is updated at 9:00 and the next update

occurs at 9:02, the window (including the graph) does not display the monitoring result for the

period of 9:00 to 9:01. This situation occurs when you use a Remote Web Console computer,

as well as when the SVP is used to perform maintenance operations for the DKC.

Replacing the micro program

After the micro program was replaced, the monitoring data is not stored until a service engineer

releases the SVP from Modify mode.

XP24000 Performance Monitor User's Guide