Table 34 MPX200 log messages (continued)

Left power and cooling module (PCM)
is or has been installed.

Info

User

sysTempMon: Left PCM Installed

152129

Left PCM is or has been uninstalled.

Info

User

sysTempMon: Left PCM

Un-installed

152130

Right PCM is or has been installed.

Info

User

sysTempMon: Right PCM Installed

152131

Right PCM is or has been uninstalled.

Info

User

sysTempMon: Right PCM

Un-installed

152132

Left PCM is connected AC power.

Info

User

sysTempMon: Power for Left PCM

Plugged-in

152133

Left PCM is not connected to AC
power (unplugged).

Info

User

sysTempMon: Power for Left PCM

Un-plugged

152134

Right PCM is connected AC power.

Info

User

sysTempMon: Power for Right PCM

Plugged-in

152135

Right PCM is not connected to AC
power (unplugged).

Info

User

sysTempMon: Power for Right PCM

Un-plugged

152136

Left PCM (#1) is reporting a faulty fan.

Info

User

sysTempMon: Slot 1 (R1) PCM

Fan%d faulty

152137

Left PCM (#1) is reporting a healthy
fan.

Info

User

sysTempMon: Slot 2 (R2) PCM

Fan%d faulty

152138

Right PCM (#2) is reporting a faulty
fan.

Info

User

sysTempMon: Slot 1 (R1) PCM

Fan%d healthy

152139

Right PCM (#2) is reporting a healthy
fan.

Info

User

sysTempMon: Slot 2 (R2) PCM

Fan%d healthy

152140

Router has detected an over
temperature, Front: %dC Rear: %dC
CPU1: %dC CPU2: %dC.

Info

User

sysTempMon: Over Temperature

Front: %dC Rear: %dC CPU1: %dC

CPU2: %dC

152141

Fan(s) speed has been set to high.

Info

User

sysTempMon: Setting the fan

speed to high

152142

Fan(s) speed has been set to normal.

Info

User

sysTempMon: Setting the fan

speed to normal

152143

Router temperature has returned to
normal operating range, Front: %dC
Rear: %dC CPU1: %dC CPU2: %dC.

Info

User

sysTempMon: Temperature back to

safe value. Front: %dC Rear:

%dC CPU1: %dC CPU2: %dC

152144

Router has reached a critical
temperature ad is shutting down,

Info

User

sysTempMon: Critical

Temperature, Shutting Down

152145

Front: %dC Rear: %dC CPU1: %dC
CPU2: %dC.

Front: %dC Rear: %dC CPU1: %dC

CPU2: %dC

This is an informative message, not an
error. It indicates that an FCIP was
removed or modified.

Error

FCIP

FcipRoute#%d: Cleaning FCIP

Instance

172040

FCIP route #n has not been able to
communicate with the remote peer for
10 seconds.

Error

FCIP

FcipRoute#%d: Did not get the

keepalive msg form remote peer

172231

FCIP route #n local node is out of sync
with the remote peer.

Error

FCIP

FcipRoute#%d: Synchronization

Error on Receive

172238

FCIP route #n detected an error in
de-compression.

Error

FCIP

FcipRoute#%d: Decompression

Error on Receive

172239

230 Log messages