Advance Planning

ADVANCE PLANNING

Ductwork Planning

• These vent hoods are equipped for 8" round

ductwork.

• Determine the exact location of the vent hood.
• Plan the route for venting exhaust to the outdoors.
• Use the shortest and straightest duct route

possible. For satisfactory performance, duct run

should not exceed 100 ft. equivalent length for any

duct configurations.

• Refer to “Duct Fittings” chart to compute the

maximum permissible length for duct runs to the

outdoors.

• Use rigid metal ductwork only.
• Install a roof cap with damper at the exterior

opening. Order the cap and any transitions needed

in advance.

• When applicable, install any makeup (replacement)

air system in accordance with local building code

requirements. Visit GEAppliances.com for available

makeup air solutions.

Ceiling Framing for Adequate Support
• These vent hoods are heavy. Adequate structural

support must be provided. The ceiling structure
must be capable of supporting the weight of the
hood and any inadvertent user contact loads
(approximately 200 pounds). The hood support
frame will be supported by 2 x 4 cross framing.

• Installation will be easier if the vent hood is

installed before the cooktop or countertop below is
installed.

Accessory Duct Cover
• All models are shipped with a duct cover for ceiling

heights of 7'-11" to 9'.

POWER SUPPLY

IMPORTANT - (Please read carefully)

WARNING:

FOR PERSONAL SAFETY, THIS APPLIANCE MUST BE
PROPERLY GROUNDED.

ATTENTION :

POUR DES RAISONS DE

SÉCURITÉ, CET APPAREIL DOIT ÊTRE CORRECTEMENT
MIS À LA TERRE.
Remove house fuse or open circuit breaker before
beginning installation.
Do not use an extension cord or adapter plug with
this appliance. Follow National electrical codes or
prevailing local codes and ordinances.
Electrical Supply
This vent hood must be supplied with 120V, 60Hz,
and connected to an individual, properly grounded
branch circuit, and protected by a 15 or 20 amp
circuit breaker or time delay fuse.
• Wiring must be 2 wire with ground.
• If the electrical supply does not meet the above

requirements, call a licensed electrician before
proceeding.

• Route house wiring in the ceiling, as close to the

installation location as possible. Allow additional
length from ceiling joists to reach the junction
box on the bottom of the hood support frame.

• Connect the wiring to the house wiring in

accordance with local codes.

Grounding Instructions
The grounding conductor must be connected to
a ground metal, permanent wiring system, or an
equipment-grounding terminal or lead on the hood.

WARNING:

The improper connection of

equipment-grounding conductor can result in a risk

of electric shock. Check with a qualified electrician

or service representative if you are in doubt

whether the appliance is properly grounded.

AVERTISSEMENT :

Le mauvais branchement du fil de mise à la terre

peut causer un choc électrique. En cas de doute,

consultez un électricien qualifié ou un technicien

pour déterminer si l’appareil est à la terre.

4

ZX92510 accessory 36-3/4"duct cover is

available to reach 9'-1"to 10'-1" ceiling heights.

The accessory should be ordered with the hood

and be on site before final framing and wall

finishing.