Out-of-band network management allows you to configure,
manage, and monitor the IntraSwitch and each of its ports. You
can perform these functions via the following method:

By attaching a terminal (or a terminal emulator)
to the IntraSwitch’s Console port and using the
menu-driven Local Management Interface.

Out-of-band network management is guaranteed even when the
in-band Ethernet network is down.

To access the IntraSwitch’s Local Management Interface using
out-of-band management:

1

Connect a stand-alone terminal or a PC running
a terminal emulator directly to the IntraSwitch’s
Console port using a

straight-thr

ough

RS-232

serial cable with a male connector.

Figure 4-2

Connecting to the Console port

2

Make sure both units are powered on.

If using a PC with a terminal emulator, make
sure it is configured with the following terminal
settings:

❏ Bits Per Second: 9600

❏ Data Bits: 8

❏ Parity: None

❏ Stop Bits: 1

❏ Flow Control: None