Appendix 2: Display commands
M210282en-A
68
Selecting parity:
Selecting data bits:
Selecting stop bits:
Full duplex/half duplex:
The processor does not allow the following combinations:
•
no parity, 7 data bits, 1 stop bit: if this combination is given the
HMP228 programme will change the number of stop bits to 2
•
even or odd parity, 8 data bits, 2 stop bits: if this combination is given
the programme changes the number of stop bits to 1
NOTE
The serial bus settings become effective only after reset.
1.1.1.3
Setting the transmitter address
Address is used when more than one transmitter is connected to one serial bus;
it makes it possible to communicate with one transmitter at a time.
•
Select More in the main menu and Addr in the More menu; the
following is displayed: