PROGRAM PRESETS & COUNTER LOAD MODULE

The Preset and Counter Load values are accessed from any of the

indication displays, or from any of the main menus in the programming loop,
by pressing the PRS key. The top line indicates which display the preset is
assigned to. The bottom line indicates which preset is viewed and the
programmed value. The following flowchart shows only the Preset and
Counter Load portion:

PRESET VALUES

Preset values P1 through P6 can activate solid state outputs 01-SNK

through 06-SNK respectively, when the assigned display equals the preset
value. Presets P1 to P6 can be assigned to the count or rate displays. The
output action (timed, latched, or boundary) is programmed in the Program
Outputs Module. The preset values may range from -99,999 to 999,999.

The Count Scale Factor, has a direct effect on the preset value entered,

when the output (preset) is assigned to a counter display. For a Scale Factor
Value greater than “1”, the preset value should be a whole number multiple of
the Scale Factor value. If it is not, the unit automatically adjusts the preset
value up or down to force it to be evenly divisible by the Scale Factor.

COUNTER LOAD VALUE

The Counter Load (CL) value allows the user to start the count value from a

value other than zero or a preset. The reset mode is set in the Program Counter
Module. The Counter Load value can be programmed from -99,999 to 999,999.

-13-