Program options module 36, Operator access 36, Preset tracking 36 – Red Lion LEGEND User Manual

Page 38: Program code (pro.code) 36

Advertising
background image

PROGRAM OPTIONS MODULE

The Program Options module is used to program the Operator Accessible

functions, Preset Tracking selections, the Programmable Code value, or load
the Factory Settings. The flowchart shows only the Options portion.

OPERATOR ACCESS

The Operator Access menu is used with the Program Disable DIP switch

and/or an external User Input selected for program disable. Values can be set
for YES, NO, or LOC. When a value is selected for NO, the operator can view
the value, but CANNOT change it from the front panel keypad (See Front Panel
Accessible Functions With Program Disable for details). Values selected for
LOC do not appear in the displays outside of the programming loop. The
following values can be disabled from front panel access programming:

Preset 1

Preset 5

Preset 2

Preset 6

Preset 3

Counter Load value

Preset 4

Scale Factors

PRESET TRACKING

If Preset Tracking is enabled and a preset value is changed, the preset value

that is tracking it will also change by the same offset. The amount of offset
between presets is changed by changing the preset value doing the tracking
first. Example: Preset 1 is tracking Preset 2. If Preset 2 is 100 and it is desired
that Preset 1 occurs 20 counts before Preset 2, the Preset 1 value would be set
to 80. If Preset 2 is then changed to 200, Preset 1 will automatically change to
180, maintaining the same 20 count Offset. All presets can be set to track a
different preset if they are assigned to the same function (rate or count). If
only one preset is selected for a particular function then that preset cannot be
used for preset tracking.

PROGRAM CODE (PRO.CODE)

The value can be programmed from 0 to 99. This value may be required to

be entered before the unit allows access to programming menus, depending
on the level of security that has been chosen. Programming a value of 99
disables access to programming menus when PGM.DIS. switch is on. Refer to
“Front Panel Accessible Functions with Program Disable.”

-36-

Advertising