14. CERTIFICATIONS AND COMPLIANCES:

SAFETY

IEC 6 1 0 1 0 -1 , EN 6 1 0 1 0 -1 : S a f e t y req u i remen t s f o r e l e c t ric a l

equipment for measurement, control, and laboratory use, Part 1.

IP65 Enclosure rating (Face only), IEC 529
Type 4X Indoor Enclosure rating (Face only), UL50

ELECTROMAGNETIC COMPATIBILITY

Immunity to EN 50082-2

Electrostatic discharge

EN 61000-4-2

Level 2; 4 Kv contact
Level 3; 8 Kv air

Electromagnetic RF fields

EN 61000-4-3

Level 3; 10 V/m
80 MHz - 1 GHz

Fast transients (burst)

EN 61000-4-4

Level 4; 2 Kv I/O

1

Level 3; 2 Kv power

RF conducted interference

EN 61000-4-6

Level 3; 10 V/rms

1

150 KHz - 80 MHz

Power

frequency magnetic fields

EN 61000-4-8

Level 4; 30 A/m

Emissions to EN 50081-2

RF interference

EN 55011

Enclosure class A
Power mains class A

Note:
1. When the unit is DC powered from terminal TBA pin 5 (common) and

terminal TBA pin 3 (DC OUT/IN) a power line filter was installed,
RLC #LFIL0000 or equivalent, so as not to impair the function of
the unit.

Refer to EMC Compliance Installation for additional information

15. CONSTRUCTION: High impact plastic case with clear viewing

window. This unit is rated for NEMA 4X/IP65 indoor use. Installation
Category II, Pollution Degree 2. Panel gasket and mounting clips included.

16. WEIGHT: 1.5 lbs. (0.68 Kg)