DECIMAL POINT (CNT. DP, RATE DP)

There are six Decimal Point locations available for the Rate and Count

displays. The decimal point position is programmed individually for each
display. The decimal point location programmed for the Rate display is the
same for the Peak and Valley displays.

CHANGE COUNT VALUE WITH SCALE FACTOR (CHG CNT W/SF)

When yes is selected for this option, any changes to the count scale factor

adjusts the currently displayed count value to reflect the new scale factor. If
this option is set to no, the internal count value is modified so that the count
display value is not affected.

Example; The count scale factor of an LGPM with a count value of 36 is

changed from 1.000 to 0.500. If the option is set to yes, the new count value
would be 18. If the option was selected as no, the count display value would
remain at 36.