VIEW/FREEZE DISPLAY (VIEW DS1)

When View Display is activated, the programmed indication display is

viewed and the numeric value for that display is held. This is a maintained
action. If the operator is in the main display loop, the unit advances to the
indication display to be viewed. If more than one User Input is programmed
for this option, the input with the highest priority is the only one that holds
(freezes) the display and advances from the main display loop. Any other
User Input programmed only advances in the indication display loop. The
priority order is F2, F1, USR INP4, USR INP3, USR INP2, and USR INP1,
with F2 the highest priority. DS1 selects display 1, DS2 display 2, etc. The
values that are viewed/frozen on the display are determined by what is
selected in the Program Displays Module.

Activation of a User Input programmed for View Display will suspend any

displayed message for 2.5 seconds. The User Input has a higher priority in this
instance.

CHANGE DISPLAY (CHG DSP)

In the indication display loop, when a User Input is activated, the

indication display toggles to the next indication display. The change of
display is a momentary action.

Activation of a User Input programmed for Change Display will suspend

any displayed message for 2.5 seconds.

REQUEST MESSAGE (REQ MSG#)

The selected message is requested when the User Input is activated. This

may be a maintained or momentary request, as selected in the Program
Message Module.

CLEAR MESSAGE (CLR MSG)

When the User Input is activated, the displayed message is cancelled. This

is a maintained action. While this input is held active, it prevents messages
from being requested. Only one User Input should be programmed for the
Clear Message function.

SKIP PRESET (SKIP PRS)

Up to 6 Presets can be set to be skipped using one User Input. When the

User Input is activated, the output does not activate/deactivate when the
count/rate output conditions are met. This includes an Automatic Reset at
Preset. The counter continues to count through the preset.
Note: An individual preset may be programmed to be skipped on only one User

Input. Other User Inputs may be programmed for skipping presets only if the
presets selected are not programmed to be skipped elsewhere.

COUNTER LOAD (CNT LD)

The count value is set to the counter load value, regardless of the reset

action programmed in the Program Counter Module. The Counter Load is a
maintained action.

PRINT REQUEST (PRINT RQ)

When a User Input is activated, the unit transmits all the information

selected in the Print Options Module via the serial port. The print request is a
maintained action.

PROGRAM DISABLE (PGM.DIS.)

This option used with the Program Disable DIP switch can limit operator

access to programmable parameters (Refer to Operator Accessible Functions
With Program Disable section). Only one external User Input can be used for
this option. The program disable is a maintained action. If the User Input, set
for PGM.DIS., is changed to another function, make sure the User Input is not
low (active). If the input is low when the function is changed, the program
disable function is still active for the User Input.

INHIBIT COUNT

When active, the Inhibit Count function prevents pulses from being

counted on Inputs A & B. The Inhibit Count is a maintained action. The rate
input is not affected by the Inhibit function, and continues to indicate the rate
of the signal at Input A. This function is only available on User Input 4.