Uact, Usrn, Inpt – Red Lion PAX2C User Manual

Page 15: User, User ), None, Ploc, Iloc, Trnf, Spsl

Advertising
background image

15

F1

F2

P

D

Pro

N O

Pro

I N P t

INPt

P2C

U S E r

USEr

P2C

U A C t

USEr

P2C

U S r 1

USEr

P2C

U S r 2

USEr

P2C

F 1

USEr

P2C

F 2

USEr

P2C

S C F 1

USEr

P2C

S C F 2

Function Keys

User Inputs

The two user inputs are individually programmable to perform specific meter control functions. While in the Display Mode or Program Mode, the function is

executed the instant the user input transitions to the active state. The front panel function keys, ! and @, are also individually programmable to perform specific

control functions. While in the Display Mode, the primary function is executed the instant the key is pressed. Holding the function key for three seconds executes a

secondary function. It is possible to program a secondary function without a primary function.

In most cases, if more than one user input and/or function key is programmed for the same function, the maintained (level trigger) actions will be performed while

at least one of those user inputs or function keys are activated. The momentary (edge trigger) actions will be performed every time any of those user inputs or function

keys transition to the active state.

Note: In the following explanations, not all selections are available for both user inputs and front panel function keys. Displays are shown with each selection. Those

selections showing both displays are available for both. If a display is not shown, it is not available for that selection. USEr-n will represent both user inputs. Fn will

represent both function keys and second function keys.

USER INPUT ACTIVE STATE

Lo

Hi

Select the desired active state for the User Inputs. Select Lo for

sink input, active low. Select Hi for source input, active high.

NO FUNCTION

No function is performed if activated. This is the

factory setting for all user inputs and function keys.

PROGRAMMING MODE LOCK-OUT

Programming Mode is locked-out, as long as activated (maintained

action). A security code can be configured to allow programming

access during lock-out.

INTEGRAL ACTION LOCK

Integral Action of the PID computation is disabled as

long as activated (USr = maintained action; Fn = toggle).

AUTO/MANUAL MODE

Places the controller in manual (user) mode as long as

activated (USr = maintained action; Fn = toggle). The

output is “bumpless” when transferring to/from either

operating mode.

SETPOINT SELECTION

When activated (USr = maintained action; Fn =

toggle), the controller uses Setpoint 2 (SP2) as the active

setpoint value.

PID PARAMETER SELECTION

When activated (USr = maintained action; Fn =

toggle), the controller uses the Alternate P, I, D, and filter

values for control. The controller initiates a “bumpless”

transfer during each transfer in an effort to minimize any

output power fluctuation.

SETPOINT RAMPING DISABLE

When activated (USr = maintained action), setpoint

ramping is terminated and unit will operate at the target

setpoint. When user input is released, setpoint ramping

will resume at the next setpoint change.

When Function key is pressed (Fn = toggle), setpoint

ramping is terminated and unit will operate at the target

setpoint. A second press of the function key resumes

setpoint ramping at the next setpoint change.

SELECT MAXIMUM DISPLAY

The Maximum display appears on Line 2 as long as activated

(maintained). When the user input is released, the previously selected

display is returned. The

D or P keys override and disable the active

user input. The Maximum continues to function independent of the

selected display.

UACt

FNC

Lo

USrn

FNC

NONE

Fn

FNC

NONE

USrn

FNC

PLOC

USrn

FNC

ILOC

Fn

FNC

ILOC

USrn

FNC

trnF

Fn

FNC

trnF

USrn

FNC

SPSL

Fn

FNC

SPSL

USrn

FNC

PSEL

Fn

FNC

PSEL

USrn

FNC

SPrP

Fn

FNC

SPrP

USrn

FNC

d-HI

u

ser

i

npuT

/f

unCTiOn

K

ey

p

arameTers

(USEr)