4.4 USER INPUT WIRING

If not using User Inputs, then skip this section. User Input terminal does not need to be wired in order to remain in the inactive state.

Sourcing Logic (UACt Hi)

When the UACt parameter is programmed

to Hi, the user inputs of the controller are

internally pulled down to 0 V with 20 KW

resistance. The input is active when a

voltage greater than 2.2 VDC is applied.

USER COMM

USER

2

USER

1

10

11

9

USER INPUTS

OR

Sinking Logic (UACt Lo)

When the UACt parameter is programmed

to Lo, the user inputs of the controller are

internally pulled up to +3.3 V with 20 KW

resistance. The input is active when it is

pulled low (<1.1 V).

10

9

11

+

-

(30V max.)

SUPPLY

V

USER COM

M

USER

2

USER

1

USER INPUTS

OR

4.5 SETPOINT (ALARMS) WIRING
4.6 SERIAL COMMUNICATION WIRING
4.7 ANALOG OUTPUT WIRING

See appropriate plug-in card bulletin for wiring details.

5.0 r

evieWing

The

f

rOnT

b

uTTOns

and

d

isplay

DISPLAY LINE 1

Line 1 consists of a large 4-digit top line display, eight segment bar graph and

a three digit units mnemonic: Values such as Input, Max(HI) & Min (LO) may

be shown on Line 1. The eight segment bar graph may be mapped to values such

as Output Power, Deviation or Setpoints. The three digit units mnemonic

characters can be used to indicate which Line 1 display value is shown. Line 1

is a tri-colored display and may be configured to change color based on

specified alarm/logic configurations.

KEY DISPLAY MODE OPERATION

D

Index Line 2 through enabled Line 2 display values

P

Enter full programming mode or access the parameter and

hidden display loops; Press and hold to skip parameters and go

directly to Code or Programming Menu

!

User programmable Function key 1; hold for 3 seconds for user

programmable second function 1*

@

User programmable Function key 2; hold for 3 seconds for user

programmable second function 2*

*Factory setting for F1 and F2 and second function F1/F2 is no mode

KEY PROGRAMMING MODE OPERATION

D

Return to the previous menu level (momentary press)

Quick exit to Display Mode (press and hold)

P

Access the programming parameter menu, store selected

parameter and index to next parameter

!

Increment selected parameter value; Hold ! and momentarily
press @ key to increment next decade or D key to increment by

1000’s

@

Decrement selected parameter value; Hold @ and momentarily
press ! key to decrement next decade or D key to decrement

by 1000’s

DISPLAY LINE 2

Line 2 consists of a 4-digit bottom line display, eight segment bar graph and

a three digit units mnemonic. Values such as Setpoints, Output Power,

Deviation, PID Parameters/Tuning Status, List A/B Status, and Alarm Values

may be shown on the Line 2 display. The eight segment bar graph may be

mapped to values such as Output Power, Deviation or Setpoints. The three digit

units mnemonic characters can be used to indicate which Line 2 display value is

shown. Line 2 is a tri-colored display and may be configured to change color

based on specified alarm/logic configurations.

The display loops described in the next section are used to view, reset and

modify the selected display values, based on the Line 2 Value Access setting

programmed for each available value. See Line 2 parameters in the Display

Parameters programming section for configuration details.

MAN

REM

Line 1:

Display, Bar Graph

and Units

(Color Zone 1)

Line 2:

Display, Bar Graph

and Units

(Color Zone 2)

Universal Annunciators

(Color Zones 3 - 6)

Manual and Remote

Mode Mnemonics

(Color Zone 7)

Advertising