Lgic, Asel, Mn ) – Red Lion PAX2C User Manual

Page 24: Sngl, None, Disp, 2one, Colr, Orng, Gnor

Advertising
background image

24

Mnemonics

Default Color

P

D

dISP

2 O N E

F1

F2

P

D

Pro

N O

Pro

d I S P

2ONE

dSP

M n

Colr

Mn

G r n

Advanced Menu Mode Only

Mnemonics

Green

Backlight

Assignment

Mnemonics

Orange

Backlight

Assignment

Mnemonics

Red Backlight

Assignment

Mnemonics

Green-Orange

Backlight

Assignment

Mnemonics

Red-Orange

Backlight

Assignment

Mnemonics

Red-Green

Backlight

Assignment

Grn

Mn

N O N E

OrNG

Mn

N O N E

rEd

Mn

N O N E

GnOr

Mn

N O N E

rdOr

Mn

N O N E

rdGn

Mn

N O N E

MNEMONICS DISPLAY COLOR

Grn

OrNG

rEd

Enter the desired Mnemonics Display color.

Grn

= Green

OrNG

= Orange

rEd

= Red

The following programming steps are only available in the Advanced

Operating Mode.

These parameters allow the mnemonic backlights to change color, or alternate

between two colors when the mapped parameter is activated. When multiple

backlight assignments are programmed for a particular zone, the color priority

is defined as follows (from Lowest to Highest): Grn, OrG, rEd, GnOr, rdOr, rdGn

BACKLIGHT ASSIGNMENT SELECTIONS

NONE

= Backlight color change disabled

Out1

= Output 1

Out2

= Output 2

Out3

= Output 3

Out4

= Output 4

ALr

= Alarm

MAN

= Manual Control Mode

The following two programming steps are only available when the Backlight

Assignment is configured as an Alarm (Alr). These steps apply to each of the six

different backlight color assignment parameters.

ALARM LOGIC MODE

SNGL

And

Or

The PAX2C supports three different modes when an output is

assigned as an alarm:

SNGL

= Any single alarm

And

= Allows multiple alarms to be mapped to an output

using AND Boolean logic. For example: If AL1

and AL2 are active, the output will energize.

Or

= Allows multiple alarms to be mapped to an output

using OR Boolean logic. For example: If AL1 or

AL2 are active, the output will energize.

ALARM MASK ASSIGNMENT

NO

YES

Selects the alarms to be logically combined per the Alarm Logic

Mode selection. Any alarms configured as YES will be used in the

Boolean logic calculation. If the Alarm Logic Mode is assigned as

Single (SNGL), only one alarm may be selected at a time.

MNEMONICS GREEN BACKLIGHT ASSIGNMENT

NONE Out1

Out2 Out3

Out4 ALr MAN

Select the parameter to be used to activate the mnemonic Green

backlight.

MNEMONICS ORANGE BACKLIGHT ASSIGNMENT

NONE Out1

Out2 Out3

Out4 ALr MAN

Select the parameter to be used to activate the mnemonic Orange

backlight.

MNEMONICS RED BACKLIGHT ASSIGNMENT

NONE Out1

Out2 Out3

Out4 ALr MAN

Select the parameter to be used to activate the mnemonic Red

backlight.

MNEMONICS GREEN-ORANGE BACKLIGHT ASSIGNMENT

NONE Out1

Out2 Out3

Out4 ALr MAN

Select the parameter to be used to activate the mnemonic Green-

Orange backlight.

MNEMONICS RED-ORANGE BACKLIGHT ASSIGNMENT

NONE Out1

Out2 Out3

Out4 ALr MAN

Select the parameter to be used to activate the mnemonic Red-

Orange backlight.

MNEMONICS RED-GREEN BACKLIGHT ASSIGNMENT

NONE Out1

Out2 Out3

Out4 ALr MAN

Select the parameter to be used to activate the mnemonic Red-

Green backlight.

Colr

UAn

rEd

LGIC

UAn

SNGL

ASEL

UAn

NO

An

Grn

Mn

NONE

OrNG

Mn

NONE

rEd

Mn

NONE

GnOr

Mn

NONE

rdOr

Mn

NONE

rdGn

UAn

NONE

d

isplay

p

arameTers

: Z

One

C

OnfiguraTiOn

- m

nemOniCs

(Mn)