High Country Tek PLD, Powerline / universal single / dual coil PWM Valve Driver User Manual

Page 10

Advertising
background image

Part No:-

021-00155 RevD7

PowerLine System Controller User Guide

Page | 10

PowerLine User Guide









Valve Type

Coil

Voltage

Imin (mA)

Imax (mA)

Dither

Frequency

Dither

Amplitude

DAAL, DBAL, DLDA, DMDA, DNDA,
DNDC, DTCA, DTDA, DWDA, FMDA,
FMDB, PRDL, PRDM, PRDN, PRDP,
RBAN, RBAP

12

1150mA

100 –

250Hz

dependant on

valve size

DAAL, DBAL, DLDA, DMDA, DNDA,
DNDC, DTCA, DTDA, DWDA, FMDA,
FMDB, PRDL, PRDM, PRDN, PRDP,
RBAN, RBAP

24

590

100 –

250Hz

dependant on

valve size

Note: Final optimized settings are valve size and system/application dependent. Consult valve manufacturer for full details
as required

.




Valve Type

Coil

Voltage

Imin (mA)

Imax (mA)

Dither

Frequency

Dither

Amplitude

HPV – 02 – E1

12

~440 – 460

~810 - 1200

100 Hz

HPV – 02 – E1

24

~215 – 235

~410 – 600

100 Hz

Note: Final optimized settings are valve size and system/application dependent. Consult valve manufacturer for full details
as required

.






Valve Type

Coil

Voltage

Imin (mA)

Imax (mA)

Dither

Frequency

Dither

Amplitude

PRM2-04

12

~600-700

~1700

90

0-30

PRM2-04

24

~250-270

~800

60

0-30

PRM2-06

12

~700-850

~2500

90

0-30

PRM2-06

24

~270-310

~1000

60

0-30

PVRM1-063/S

12

~250-310

~1000-1200

100

-

PP2P-06

12

~300-330

~1000-1100

150

-

PRM6-10

12

~600-700

~1900

90

0-30

PRM6-10

24

~300-400

~1100

60

0-30

PVRM3-10

12

~250-290

~1500

100

-

SR4P-B2

12

~150-210

~1000

160

SR4P-B2

24

~150-210

~750

160

Note: Final optimized settings are valve size and system/application dependent. Consult valve manufacturer for full details
as required

.