Part No:-

021-00155 RevD7

PowerLine System Controller User Guide

Page | 8

PowerLine User Guide






Module Compatibility and Valve Settings:


Valve Type

Coil

Voltage

(V)

IMin

(mA)

IMax
(mA)

Dither

Frequency

(Hz)

Dither

Amplitude

(%)

PSL/V – (Size 2)

12

~450 mA

~1,160 mA

40 - 70 Hz (55)

20 - 35%

PSL/V – (Size 2)

24

~225 mA

~580 mA

40 - 70 Hz (55)

20 - 35%

PSL/V(F) – (Sizes 3 & 5)

12

~620 mA

~1,260 mA

40 - 70 Hz (55)

20 - 35%

PSL/V(F) – (Sizes 3 & 5)

24

~310 mA

~630 mA

40 - 70 Hz (55)

20 - 35%

EM 21 D(S)E

12

~50 mA

~1,200 mA

50 - 150 Hz

20 - 40%

EM 21 D(S)E

24

~25 mA

~630 mA

50 - 150 Hz

20 - 40%

EMP 21 S

12

~550 mA

~1,100 mA

50 - 150 Hz

20 - 40%

EMP 21 S

24

~240 mA

~480 mA

50 - 150 Hz

20 - 40%

EMP 21 V

12

~500 mA

~1,000 mA

50 - 150 Hz

20 - 40%

EMP 21 V

24

~200 mA

~500 mA

50 - 150 Hz

20 - 40%

EMP 21 S10

12

~40 mA

~1,300 mA

50 - 150 Hz

20 - 40%

EMP 21 S10

24

~20 mA

~650 mA

50 - 150 Hz

20 - 40%

EMP 21 V10

12

~400 mA

~1,380 mA

50 - 150 Hz

20 - 40%

EMP 21 V10

24

~200 mA

~690 mA

50 - 150 Hz

20 - 40%

EMP 31 S

12

~240 mA

~1,200 mA

50 - 150 Hz

20 - 40%

EMP 31 S

24

~120 mA

~600 mA

50 - 150 Hz

20 - 40%

EMP 31 V

12

~400 mA

~1,000 mA

50 - 150 Hz

20 - 40%

EMP 31 V

24

~200 mA

~500 mA

50 - 150 Hz

20 - 40%

EMP 31 S10

12

~150 mA

~1,200 mA

50 - 150 Hz

20 - 40%

EMP 31 S10

24

~75 mA

~600 mA

50 - 150 Hz

20 - 40%

EMP 31 V10

12

~400 mA

~1,560 mA

50 - 150 Hz

20 - 40%

EMP 31 V10

24

~200 mA

~780 mA

50 - 150 Hz

20 - 40%

EMP 41 S

12

~100 mA

~870 mA

50 - 150 Hz

20 - 40%

EMP 41 S

24

~200 mA

~1,750 mA

50 - 150 Hz

20 - 40%

EMP 41 V

12

~100 mA

~870 mA

50 - 150 Hz

20 - 40%

EMP 41 V

24

~200 mA

~1,750 mA

50 - 150 Hz

20 - 40%

PMV

12

~200 mA

~1,260 mA

60 - 150 Hz

20 - 40%

PMV

24

~100 mA

~630 mA

60 - 150 Hz

20 - 40%

PDM, PDV

12

~190 mA

~1,200 mA

50 - 150 Hz

20 - 40%

PDM, PDV

24

~110 mA

~680 mA

50 - 150 Hz

20 - 40%

PM(Z)

12

~200 mA

~1,260 mA

50 - 150 Hz

20 - 40%

PM(Z)

24

~100 mA

~630 mA

50 - 150 Hz

20 - 40%

SE - (Sizes 2 & 3)

12

~380 mA

~1,900 mA

60 - 150 Hz

20 - 40%

SE - (Sizes 2 & 3)

24

~190 mA

~950 mA

60 - 150 Hz

20 - 40%

SEH - (Sizes 2 & 3)

12

~250 mA

~1,260 mA

60 - 150 Hz

20 - 40%

SEH - (Sizes 2 & 3)

24

~130 mA

~630 mA

60 - 150 Hz

20 - 40%

SWS 2

12

~400 mA

~1,350 mA

50 - 150 Hz

20 - 40%

SWS 2

24

~260 mA

~880 mA

50 - 150 Hz

20 - 40%

V30D "V" Controller

24

~250 mA

~750 mA

80 - 100 Hz

20 - 40%


Note:
Final optimized settings are valve size and system/application dependent. Consult valve manufacturer for full details
as required

.

Advertising