Part No:-

021-00155 RevD7

PowerLine System Controller User Guide

Page | 26

PowerLine User Guide

Command Input Setup:

Selection from Menu-> Command Input Setup

Command Error Detection
Enabled when checked disabled when
unchecked



Command Error = coils off
(active if command error detection = true)

activates when a command error is detected.

Coils turned off when checked, command
would go to “Command Error Default Volts”
when unchecked.


Command Range
Max - voltage to determine end of joystick travel
Center – Pot/joystick center point voltage
Min - voltage to determine end of joystick travel


Command Selection
0 to +5V or 0 to +10V or 4 to20mA options.


Command Error Default Volts -

(active if command error detection = true) activates when a command error is

detected
If the unit senses a command error, this voltage value will be read by the card as the command voltage until the
error is corrected.


Command Error Limits -

(active if command error detection = true)

The Command Error Limits feature will detect and report errors on the Command Input that exceed the user
defined set points.



NOTE:
If the command input value is outside the High and Low values entered here, the modules outputs will
be determined by the ‘Command Input Error’ settings


These settings are used when the Command Error Detection check box has been checked.

High - Command Input Error reported when command volts are greater than High.
Low - Command Input Error reported when command volts are less than Low.