PowerLine User Guide


Advanced Settings:

Selection from Menu-> Advanced Settings



Process P and I Term Scale
These values allow for scaling the P and I term scale.
These values are only editable when the controller is in
RPM Regulation Mode. These values represent the
number of times to divide the effect of the P or I term by
two. Therefore, larger shift values will increasingly reduce
the effects of the P and I terms. The P shift value can be
from 0 to 7 (default = 5). The I shift value can be from 0 to
7 (default = 7). These setting should only be changed
when the use of process P, I and I time values were not
able to tune the process. (Refer to Tuning a PID controller)










NOTE:

These settings are pre-set for optimal response and are only available with the correct password please contact
HCT factory for further information.