Part No:-

021-00155 RevD7

PowerLine System Controller User Guide

Page | 21

PowerLine User Guide

Horse Power Limiter & Anti Stall Mode with Reverse

Selection from Menu ->

Control Logic -> Anti-Stall Mode with Reverse

The PowerLine controller has a new useful
function that combines Anti-stall with a
reverse feature.

This feature will allow the user to set up the
anti-stall as normal with ‘SLOW’ and
‘STOP’ limits, with the difference being that
if the monitored RPM reaches the ‘STOP’
limit, the controller will turn the PWM% A
output fully off, then turn the PWM% B on
to offer a reverse feature.

The ramps used for the PWM% A and
PWM% B are set in the process setup
window as shown here.
























IMPORTANT NOTE: Reverse feature ON/OFF setting


The reverse feature is turned OFF by setting the ‘Auto Reverse Time’ to 0 (ZERO) seconds.
The auto reverse feature is turned ON if there is any time entered in the ‘Auto Reverse Time’ box.
The minimum reverse time is 0.5 seconds while the max is ~85 seconds.

RPM

PWM% A

PWM% B

100mS

Dwell

100mS
Dwell

STOP

Setpoint

Output A to

ZERO

Normal RPM level

PWM% A – Full ON

PWM% B – Full OFF

Auto Reverse

Time

Ramp
PWM% A
UP setting

Ramp

PWM% B

DOWN

setting

Ramp
PWM% B
UP setting

Ramp set
by rate of
RPM
decline

SLOW

Setpoint

Advertising