Control logic – High Country Tek PLD, Powerline / universal single / dual coil PWM Valve Driver User Manual

Page 18

Advertising
background image

Part No:-

021-00155 RevD7

PowerLine System Controller User Guide

Page | 18

PowerLine User Guide




Selection from Menu ->

Restore Temporary Memory from Permanent Memory


Restores settings stored in permanent memory to temporary (operational) memory.

Caution:

Use of this selection temporarily prevents the unit from working in the system.

Do not select this option while the machine is operating.

Selection from Menu ->

Restore Temporary & Permanent

Memory from a File


When this selection is made, the user is prompted for a file
name and location from which to retrieve settings. The
restored values are placed in temporary and permanent
memory.

Caution:

Use of this selection temporarily prevents the

unit from working in the system.
Do not select this option while the machine is operating.




Control Logic:

This drop down menu allows the user to
select what control mode the controller will
operate in:

1. Manual PWM control

( Set-up )

2. Anti-Stall

(Reverse option available)

3. Anti-Stall with Max Command

4. Valve Control

( Single or dual coil )

IMPORTANT NOTE – DUAL COIL OPERATION:


The output of either ‘A’ or ‘B’ output will go from the respective ‘I Min’ setting to ZERO (0mA ) when crossing
through command mid-point. The valve outputs do NOT jump from one I Min to the other.