Color pattern, Color value, Description – MagTek MICRImage User Manual

Page 32: Note, Dm – disable micrimage command, Table 3-1. led control

Advertising
background image

MICRImage Check Reader


24

For example, to setup a color pattern where the LED illuminates green-red-green-red, the byte value
would be “01100110” (decimal 102). The decimal value of this byte is used with the LE command. In this
example, the LE command is executed as follows:

LE 102<CR>

Table 3-1 lists common color patterns with their values and descriptions:

Table 3-1. LED Control

Color Pattern

Color Value

(Decimal)

Description

Off/Off/Off/Off 0

LED

Off

Green/Green/Green/Green 85

Steady

Green

Red/Red/Red/Red/ 170

Steady

Red

Amber/Amber/Amber/Amber 255

Steady

Amber

Green/Green/Off/Off 80

Blink

Green

Slow

Red/Red/Off/Off

160

Blink Red Slow

Amber/Amber/Off/Off

240

Blink Amber Slow

Red/Red/Green/Green

165

Blink Red/Green Slow

Green/Off/Green/Off

68

Blink Green Fast

Red/Off/Red/Off

136

Blink Red Fast

Amber/Off/Amber/Off

204

Blink Amber Fast

Red/Green/Red/Green 153

Blink Red/Green Fast

Red/Green/Off/Off 144

Fast Red/Green Off

Green/Green/Green/Red

86

Green + Fast Red

Red/Red/Red/Green

169

Red + Fast Green

Once the color pattern is defined, the pattern is repeated for a default interval of 3 seconds. A different
time period can be specified using the LE command and providing a new value in seconds, up to 65. For
example, to setup a 5 second interval for the color pattern above, the LE command is executed as follows:

LE 85,5<CR>

Note

The total time for each color pattern is 0.4 seconds (i.e. each segment lasts 0.1 seconds).

DM – DISABLE MICRIMAGE COMMAND

This command disables the document reading function and turns off the LED. Communications are not
affected, and Insta-change checks may still be scanned, but the MICR line will not be sent.

DM<CR>

Insta-change checks only may be scanned

DMX<CR>

No scans at all

Advertising