MagTek MICRImage User Manual

Page 70

Advertising
background image

MICRImage Check Reader

62


Fmt 68xx:

[transit] <TAB> [acct #] <TAB> [check #] <TAB> [amount] <TAB>


[transit]:

- all characters in the field

-

remove

dashes


[acct #]:

- maximum of xx characters; when xx=00 all characters are sent

- remove spaces and dashes


[check #]:

- all characters in the field

- remove dashes and spaces


[amount]:

- all characters in the field

- remove dashes, spaces and leading zeros

- insert decimal point ('.') before 2nd rightmost digit


Fmt 69xx:

Read OK : [transit] [acct #] [check #]


Read

error: '0' '/'


[transit]:

- all characters in the field

-

remove

dashes


[acct #]:

- always xx characters, trailing spaces;

when xx=00 all characters are sent

- remove spaces and dashes


[check #]:

- always 6 characters, zero filled

- remove dashes and spaces

Fmt 70:

[transit] ',' [acct #] ',' [check #] ',' [amount]


[transit]:

- all characters in the field

-

keep

dashes


[acct #]:

- always N characters (N is on quick-init check), space filled

- remove spaces and dashes from the account


[check #]:

- always 8 characters, zero filled

- remove dashes and spaces


[amount]:

- all characters in the field

- remove dashes and spaces

- if amount is not present, remove last ','

Advertising