EM – ENABLE MICRIMAGE COMMAND

This command enables the document reading function, and the LED will turn green. To execute, send the
EM command followed by a carriage return as follows:

EM<CR>

One of the following optional parameters may be used:

N

Suppresses MICR for next scan regardless of SWF. Afterwards, revert to
SWF.

M

Detect MICR for next scan regardless of SWF. Afterwards, revert to SWF.

Example: EMN<CR>

BLK – BLOCK COMMAND

The BLK Command allows an application on any port to temporarily block command processing on all
other ports for a set period of time, by default 10 seconds, or until the UNBLK command is sent.
Optionally the duration (in seconds) can be specified as ‘BLK n’ where n can range from 0 to 65. Setting
the duration to 0 will allow blocking with no timeouts.

BLK<CR>

10-second timeout

BLK 15<CR>

15-second timeout


UNBLK – UNBLOCK COMMAND

The UNBLK command allows the MICRImage to continue processing input from all available ports.

UNBLK<CR>