MagTek MICRImage User Manual

Page 68

Advertising
background image

MICRImage Check Reader

60


Fmt 60xx:

[transit] '/' [acct #] '/' [check #] '/' [check type]


• [transit]:

- all characters in the field

-

remove

dashes


• [acct #]:

- maximum of xx characters; when xx=00 all characters are sent

- remove spaces and dashes


• [check #]:

- maximum of 10 characters

- remove spaces and dashes

- if no check #, remove preceding slash ('/')


• [check type]:- personal checks ('1'); commercial checks ('2')

Fmt 61xx:

[transit] <TAB> [acct #] <TAB> [check #] <TAB>


• [transit]:

- all characters in the field

-

remove

dashes


• [acct #]:

- maximum of xx characters; when xx=00 all characters are sent

- remove spaces, dashes and leading zeros


• [check #]:

- all characters in the field


Fmt 62xx:

'T' [transit] 'T' [acct #] 'A' [check #] 'S' [status]


• [transit]:

- all characters in the field

-

remove

dashes


• [acct #]:

- maximum of xx characters; when xx=00 all characters are sent

- remove spaces and dashes


• [check #]:

- all characters in the field

- remove dashes and spaces


• [status]:

- this is a programmable option that must be enabled (See Table 2-4).


Fmt 63xx:

[transit] [acct #] [check #]

• [transit]:

- all characters in the field

-

remove

dashes


• [acct #]:

- maximum of xx characters; when xx=00 all characters are sent

- remove spaces and dashes


• [check #]:

- always 4 characters, zero filled

- remove spaces and dashes