Pr5 – gateway ip address source (ethernet only), Pr6 – ftp name/ip address fixed value, Pr7 – ftp ip address source – MagTek MICRImage User Manual
Page 50: Pr8 – ftp user id fixed value, Pr9 – ftp user id source, Pr10 – ftp password fixed value, Pr11 – ftp password source, Example, Tc<cr, May return
MICRImage Check Reader
42
PR5 – Gateway IP Address Source (Ethernet Only)
PR5=0
- sets unit to configure the gateway IP using DHCP option 3
PR5=1
- sets unit to use fixed value (see PR4)
PR6 – FTP Name/IP Address Fixed Value
This sets the name or fixed IP address for the FTP server. The maximum allowable length is 100
characters. For example:
PR6=192.11.12.127<CR>
or
PR6=ftp.checks.com<CR>
PR7 – FTP IP Address Source
PR7=0
- sets unit to config the FTP server IP using DHCP option 181 (Ethernet only)
PR7=1
- sets unit to use fixed value (see PR6)
PR8 – FTP User ID Fixed Value
This sets the user ID used for the FTP server. The maximum allowable length is 16 characters. For
example:
PR8=MICRIMAGE<CR>
PR9 – FTP User ID Source
PR9=0
- sets unit to config the FTP User ID using DHCP option 179 (Ethernet only)
PR9=1
- sets unit to use fixed value (see PR8)
PR10 – FTP Password Fixed Value
This sets the fixed password used for the FTP server. The maximum allowable length is 16 characters.
For example:
PR10=CHECKREADER<CR>
PR11 – FTP Password Source
PR11=0
- sets unit to config the FTP password using DHCP option 180 (Ethernet only)
PR11=1