Pr5 – gateway ip address source (ethernet only), Pr6 – ftp name/ip address fixed value, Pr7 – ftp ip address source – MagTek MICRImage User Manual

Page 50: Pr8 – ftp user id fixed value, Pr9 – ftp user id source, Pr10 – ftp password fixed value, Pr11 – ftp password source, Example, Tc<cr, May return

Advertising
background image

MICRImage Check Reader


42

PR5 – Gateway IP Address Source (Ethernet Only)

PR5=0

- sets unit to configure the gateway IP using DHCP option 3

PR5=1

- sets unit to use fixed value (see PR4)

PR6 – FTP Name/IP Address Fixed Value

This sets the name or fixed IP address for the FTP server. The maximum allowable length is 100
characters. For example:

PR6=192.11.12.127<CR>

or

PR6=ftp.checks.com<CR>
PR7 – FTP IP Address Source

PR7=0

- sets unit to config the FTP server IP using DHCP option 181 (Ethernet only)

PR7=1

- sets unit to use fixed value (see PR6)


PR8 – FTP User ID Fixed Value

This sets the user ID used for the FTP server. The maximum allowable length is 16 characters. For
example:

PR8=MICRIMAGE<CR>

PR9 – FTP User ID Source

PR9=0

- sets unit to config the FTP User ID using DHCP option 179 (Ethernet only)

PR9=1

- sets unit to use fixed value (see PR8)


PR10 – FTP Password Fixed Value

This sets the fixed password used for the FTP server. The maximum allowable length is 16 characters.
For example:

PR10=CHECKREADER<CR>

PR11 – FTP Password Source

PR11=0

- sets unit to config the FTP password using DHCP option 180 (Ethernet only)

PR11=1

- sets unit to use fixed value (see PR10)

Advertising